期刊文献+

Coupling microchip electrophoresis with MALDI-TOF-MS based on a freezing technique 被引量:2

Coupling microchip electrophoresis with MALDI-TOF-MS based on a freezing technique
原文传递
导出
摘要 A freezing technique protocol was proposed for coupling microchip electrophoresis with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALD1-TOF-MS).The microfluidic flow was frozen immediately after electrophoresis on microfluidic chip and the separated analyte molecules were kept in their zone pattern in the electrophoresis.Then,the frozen-chip was lyophilized and sent into TOF-MS instrument as a MALDI target,and the analyte molecules in the microfluidic channels were subjected to analysis by mass spectrometry.This approach could eliminate sample cross-contamination, providing a new interface for microchip electrophoresis and MALDI-MS. A freezing technique protocol was proposed for coupling microchip electrophoresis with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALD1-TOF-MS).The microfluidic flow was frozen immediately after electrophoresis on microfluidic chip and the separated analyte molecules were kept in their zone pattern in the electrophoresis.Then,the frozen-chip was lyophilized and sent into TOF-MS instrument as a MALDI target,and the analyte molecules in the microfluidic channels were subjected to analysis by mass spectrometry.This approach could eliminate sample cross-contamination, providing a new interface for microchip electrophoresis and MALDI-MS.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2013年第6期491-493,共3页 中国化学快报(英文版)
基金 supported by National 973 Projects(No. 2010CB912704) 863 Projects(No.2012AA020202)
关键词 Microchip electrophoresis MALDI-TOF-MS Peptide analysis Freezing technique Microchip electrophoresis MALDI-TOF-MS Peptide analysis Freezing technique
  • 相关文献

参考文献17

  • 1S.C. Jacobson, J.M. Ramsey, J.P. Landers (Eds.), Handbook of Capillary Electropho- resis, CRC Press, Boca Raton, FL, 1997, p. 827.
  • 2C.S. Effenhauser, A. Manz, H. Becker (Eds.), Microsystem Technology in Chemistry and Life Science. Springer, Berlin, 1998, p. 51.
  • 3S.S. Park, S.l. Cho, M.S. Kim, Integration of on-column immobilized enzyme reactor in microchip electrophoresis, Electrophoresis 24 (2003) 200-206.
  • 4H. Nagata, M. Tabuchi, K. Hirano, High-speed separation of proteins by microchip electrophoresis using a polyethylene glycol-coated plastic chip with a sodium dodecyl sulfate-linear polyacrylamide solution, Etectrophoresis 26 (2005) 2687-2691.
  • 5S. Mouradian, Lab on a chip: application in proteomics, Curr. Opin. Chem. Biol. 6 (2002) 51-56.
  • 6P. Giron, L. Dayon, J.C. Sanchez, Cysteine tagging for MS-based proteomics, Mass Spectrom. Rev. 30 (2011 ) 366-395.
  • 7N. Liu, L.C. Zhao, C.Y. He, Advances in technologies and biological applications of O-18 labeling strategies in LC-MS based proteomics: an updated review, Curt. Anal. Chem. 8 (2012) 22-34.
  • 8R. Aebersold, M. Mann, Mass spectrometry-based proteomics, Nature 422 (2003) 198-207.
  • 9X.L. Mao, I.K. Chu, B.C. Lin, A sheath-flow nanoelectrospray interface of microchip electrophoresis MS for glycoprotein and glycopeptide analysis, Electrophoresis 27 (2006) 5059-5067.
  • 10W.C. Sung, H. Makamba, S.H. Chen, Chip-based microtluidic devices coupled with electrospray ionization-mass spectrometry, Electrophoresis 26 (2005) 1783-1791.

同被引文献6

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部