摘要 针对现有铁路大型客站在防灾设计方面存在的问题,选取通过设置应急电源的方案来提高铁路电源线路供电的可靠性,并基于武广客运专线一段长78.3km的全电缆综合贯通线实际参数建立了仿真模型,研究配电所集中设置柴油发电机作为高速铁路沿线与行车密切相关的通信、信号等重要负荷的备用电源可行性,分析线路在不同工况和不同补偿策略下的电压分布。仿真分析的结果确定了发电机进相运行的参数范围及提高发电机调节能力的条件。 In allusion to the existing problem of the disaster prevention design in grand train stations, the setting scheme of the emergency power supply to improve the supply reliability of railway power lines is selected by this paper And a simulation model is established which based on the actual parameter of a 78.3 km long full cable integrated through line in Wuhan-Guangzhou passenger dedicated line. The paper research on the feasibility that diesel generator was set in the distribution station and worked as a standby power supply of the important load, such as communication and signal along the high speed railway which is closely associated with the driving train. Voltage distribution in different conditions and different compensation strategies is also analyzed. The simulation result determine the parameter range of the generator leading running and the condition to improve the generator regulate ability
作者 陈建平
出处 《电气化铁道》 2013年第3期26-30,共5页 Electric Railway
关键词 铁路 应急电源 设置方案 仿真分析 railway emergency power supply setting scheme simulation analysis
  • 相关文献

参考文献5

二级参考文献8

  • 1TB10621-2009,高速铁路设计规范(试行)[S].
  • 2供配电系统设计规范GB50052-2009[S].
  • 3GB50217-2007,工程电缆设计规范[S].
  • 4Q/GDWl56-2006,城市电力网规划设计导则[S].
  • 5TB10009-2005,铁路电力牵引供电设计规范[S].
  • 6TB10008-2006,铁路电力设计规范[S].
  • 7TB10016-2006,铁路工程节能设计规范[S].
  • 8吴彩兰.京沪高速铁路客运站站址选择有关问题探讨[J].铁道工程学报,2009,26(12):96-101. 被引量:6

共引文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部