期刊文献+

瀍东污水处理厂提标改造工程 被引量:1

瀍东污水处理厂提标改造工程
下载PDF
导出
摘要 按照洛阳市碧水蓝天工程要求,瀍东污水处理厂正进行提标改造,使出水水质由《城镇污水处理厂污染物排放标准》(GB18918-2002)的一级B标准提升为一级A标准。提标改造工艺采用网格絮凝斜管沉淀池+纤维转盘滤池,并对原污水厂二级处理设施进行整改,以强化脱氮除磷效果。 In order to meet the requirements of clear water and blue sky project of Luoyang,Chandong Wastewater Treatment Plant are being upgraded and retrofitted. Through the upgrading and reconstruction, the effluent quality will be upgraded from the first class B criteria to the first class A criteria specified in the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant ( GB18918 - 2002). The Upgrading and reconstruction choices the pross of grid flocculation and inclined settling tank + fiber turntable filter, and will rectify the original facilities in order to strengthen the removal effect of nitrogen and phosphorus.
出处 《河南科技》 2013年第6期180-181,共2页 Henan Science and Technology
关键词 污水处理厂 提标改造 一级A标准 网格絮凝斜管沉淀池 纤维转盘滤池 wastewater treatment plant upgrading and reconstruction first class A criteria grid flocculation and inclined settling tank fiber turntable filter
  • 相关文献

参考文献2

二级参考文献12

共引文献157

同被引文献27

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部