摘要 介绍一种针对激光准直测量系统的校准方法。在50 m超长平台的基础上,设计一套校准装置,其中包括二维校准台、剪式升降台、接收靶夹具等。通过对接收靶示值误差的测量,实现激光准直测量系统的校准。通过实验比对,证实方法的有效性。 In this paper, a calibration method for laser alignment measurement system is introduced. Based on 50m ultra-long platform, a set of calibration device is proposed, including 2-D calibration table, scissor lift table, receiving target fixture and so on. By measuring the indication error of receiving target, laser alignment measurement system is calibrated. After the experimental comparison results are analyzed, the effectiveness of the proposed method is confirmed.
出处 《上海计量测试》 2013年第3期24-26,共3页 Shanghai Measurement and Testing
关键词 激光准直 接收靶 二维校准台 laser alignment receiving target: 2-D calibration table
  • 相关文献

参考文献3

二级参考文献15

  • 1[1]赵明生等.机械工程师手册(第二版).北京:机械工业出版社,2002,922~924
  • 2[2]李士雄等.电气工程师手册第三篇(第一版).北京:机械工业出版社,1987,124~128
  • 3E. Brommundt,E. Kr?mer.Instability and self-excitation caused by a gear coupling in a simple rotor system[J].Forschung im Ingenieurwesen.2005(1)
  • 4Jin Guofan,,Li Jingzheng.Laser Measurement[]..1998
  • 5Lee,G.Taking Accurate Vibration Measurements[].Http://wwwmt-onlinecom/articles/indexcfm.2004
  • 6Luedeking,A.Laser Alignment Verification—On Site at the Largest Gas Turbine in the US[]..2005
  • 7Perry,S.Dealing with positional change of on-line machinery[].Maintenance Technology.1998
  • 8Perry,S.Alignment Monitoring and Correction of a Turbine Driven Feed Water Pump[].Http://wwwludecacom.2001
  • 9Luedeking,A.Using Lasers to Align Cooling Tower Fans[].Http://wwwrsesjournalcom.2003
  • 10Studenberg,D.Precision Shaft Alignment:What‘s the Right Method For You[].Http://wwwmt-onlinecom/articles/indexcfm.2002

共引文献14

同被引文献12

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部