期刊文献+

The Behavior of New Hydrophilic Composite Bone Cements for Immediate Loading of Dental Implant 被引量:1

The Behavior of New Hydrophilic Composite Bone Cements for Immediate Loading of Dental Implant
下载PDF
导出
摘要 We introduced the hydrophilic groups to acrylic bone cement to improve compliance and achieve more interdigitation between the bone and the acrylic bone cement in order to create better substrates for immediate loading. FTIR-ATR, contact angle, and maximum breach torque were employed for measurement. The results reveal that the introduction of hydrophilic functional groups has increased PMMA's surface hydrophilicity after contact angle test. FTIR-ATR results suggest the hydrophilic groups participate in the polymerization reactions, and maximum breach torque of the hydrophilic acrylic bone cements is near 110 Ncm torque. Those effects make it possible for conventional acrylic bone cement application in immediate loading of dental implant. We introduced the hydrophilic groups to acrylic bone cement to improve compliance and achieve more interdigitation between the bone and the acrylic bone cement in order to create better substrates for immediate loading. FTIR-ATR, contact angle, and maximum breach torque were employed for measurement. The results reveal that the introduction of hydrophilic functional groups has increased PMMA's surface hydrophilicity after contact angle test. FTIR-ATR results suggest the hydrophilic groups participate in the polymerization reactions, and maximum breach torque of the hydrophilic acrylic bone cements is near 110 Ncm torque. Those effects make it possible for conventional acrylic bone cement application in immediate loading of dental implant.
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第3期627-633,共7页 武汉理工大学学报(材料科学英文版)
关键词 immediate loading hydrophilic acrylic bone cement tooth implant immediate loading hydrophilic acrylic bone cement tooth implant
  • 相关文献

参考文献44

  • 1Romanos G E, Testori T, Degidi M, et al. Histologic and Histomorphometric Findings from Retrieved, Immediately Occlusally Loaded Implants in Humans[J] J.Periodontol, 2005, 76(11): I 823-1 832.
  • 2Penarrocha M, Boronat A, Garcia B. Immediate Loading of Immediate Mandibular Implants with a Full-arch Fixed Prosthesis: a Preliminary Study[J]. J.Oral.Maxillofac.Surg., 2009, 67(6): 1 286-1 293.
  • 3Araujo M G, Sukekava F, Wennstrom J L, et al. Ridge Altera tions Following Implant Placement in Fresh Extraction Sockets an Experimental Study in the Dog[J]. J.Clin Periodontol., 2005 32(6):645-652.
  • 4Raghoebar G M, Schoen P, Meijer H J, et al. Early Loading of Endosseous Implants in the Augmented Maxilla: a l-year Prospective Study[J]. Clin.Oral.lmplants.Res., 2003, 14(6):697-702.
  • 5Degidi M, Piattelli A. 7-year Follow-up of 93 Immediately Loaded Titanium Dental Implants[J]. ,LOraLlmplantoL, 2005, 31(1):25-31.
  • 6Covani U, Crespi R, Cornelini R, et al. Immediate Implants Supporting Single Crown Restoration: a 4-year Prospective Study[J]. LPeriodontol., 2004;75(7):982-988.
  • 7S J WBF. A Retrospective Study of 1925 Consecutively Placed Immediate Implants From 1988 to 2004[J]. lnt.J.Oral.Maxillojac. Implants, 2006:71-80.
  • 8ST C. Immediate or Early Placement of Implants Following Tooth Extraction: Review of Biologic Basis, Clinical Procedures, and Outcomes[J]. lnt.J. OraLMaxillofac.lmplants, 2004, 19(supp 1 ): 12-25.
  • 9GE R. Surgical and Prosthetic Concepts for Predictable Immediate Loading of Oral Implants[J]. J. Calif Dent.Assoc., 2004, 32(12):991- 1 001.
  • 10Javed F, Romanos G E. Impact of Diabetes Mellitus and Glycemic Control on the Osseointegration of Dental Implants: a Systematic Literature Review [J]. J.PeriodontoL, 2009, 80(11):1 719-1 730.

同被引文献14