摘要 目的探讨320排CT容积扫描在心律失常患者冠状动脉血管成像中的可行性及图像质量。方法实验组心律失常29例及对照组心律正常40例行320排CT容积扫描,评价各段冠状动脉的图像质量,分析心律失常对图像质量的影响。结果 69例患者共评价冠状动脉血管754段,心率<65次/min及心率≥65次/min时,心律整齐和心律失常图像质量分布无统计学差异(P<0.05)。结论心律失常患者行冠状动脉血管成像具有可行性,心律失常患者可以不作为检查的禁忌征,扩大了冠状动脉血管成像的应用范围。 Objective To evaluate the feasibility and the image quality of 320-detector row CT coronary angiography in patients with arrhythmia. Methods 29 cases with arrhythmia and 40 cases without arrhythmia for control group underwent 320-detector CT coronary angiography, the image quality was evaluated and the effect of an'hythmia on image quality was analyzed. Results 69 cases of patients with total 754 coronary segments were evaluated. There was no statistically significant difference between the two subgroups with and without an'hythmia(P 〈 0.05) when heart-rate was below or above 65bpm. Conclusion 320-detector row CT coronary angiography is feasible in patients with arrhythmia. Arrhythmia may not be considered as a contraindication to CTCA, Which expend the applied range of CTCA.
出处 《中国CT和MRI杂志》 2013年第3期70-73,共4页 Chinese Journal of CT and MRI
关键词 心律失常 冠状动脉血管成像 X线计算机 体层摄影术 Arrhythmia Coronary Angiography: X-ray computed: Tomography
  • 相关文献

参考文献8

二级参考文献65

共引文献225

同被引文献18

  • 1Rine Nakanishi, Ronak Rajani,Yukio Ishikawa, et al. Myocardial bridging on coronary CTA: An innocent bystander or a culprit in myocardial infarction?[J].Journal of Cardiovascular Computed Tomography, 2012(6):3-13.
  • 2Olga Lazoura, Theodora Kanavou, Katerina Vassiou, et al Myocardial bridging evaluated with 128-multi detector computed tomography coronary angiography[J]. Surg Radiol Anat, 2010 (32) : 45-50.
  • 3Ferreira A G J,Trotter S E, Konig B J, et al. Myocardial bridges: morphological and functional aspects[J].Br Heart J, 1991,66(5): 364-367.
  • 4Noble J,Bourassa M G, Petitclerc R, et al. Myocardial bridging and milking effect of the left anterior descending coronary artery: normal variant or abstraction[J].Am J Cardial, 1976, 37 (7) : 993-999.
  • 5Abdel-Rauf Zeina,Majed Odeh, Jorge B1 inder, et al. Myocardial Bridge: Evaluation on MDCT[J]. AJR, 2007(188): 1069- 1073.
  • 6Calabro P, Bianchi R, Caprile M ,et al. Contemporary evidence of coronary atherosclerotic disease and myocardial bridge on left anterior descending artery in a patient with a nonobstructive hypertrophic cardiomyopathy. Journal of cardiovascular medicine (Hagerstown),2011,12(7):510- 512.
  • 7王怡宁,金征宇,孔令燕,张竹花,宋兰,张抒扬,林松柏,牟文斌,王法,赵文敏.双源CT冠状动脉成像的图像质量及重组时相与心率的关系[J].中华放射学杂志,2008,42(2):119-122. 被引量:16
  • 8林丽娟,袁小梅,何虹,龙雪银,陈凤娇.心理健康指导对多层螺旋CT冠状动脉检查患者心率及成像质量的影响[J].解放军护理杂志,2008,25(18):11-13. 被引量:5
  • 9W.P. Shuman,K.R. Branch,J.M. May,L.M. Mitsumori,D.W. Lockhart,T.J.Dubinsky,邱建星(译),唐光健(校).前瞻性和回顾性心电门控冠状动脉64层CT成像:影像质量和病人放射剂量的对照性研究[J].国际医学放射学杂志,2008,31(5):400-400. 被引量:129
  • 10孙新海,史志涛,陈月芹,张谷青,李慧,王玉红.双源CT在心律失常患者冠状动脉成像中的应用[J].中国中西医结合影像学杂志,2009,7(3):188-191. 被引量:4

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部