摘要
阐述了板式塔吸收实验的设计安装,并确定全塔正常操作范围.实验结果表明,本实验的最佳液体流量为1.17×10-5m3/h最佳空气流量范围是353~488m3/h;氨水浓度范围为0.076~0.12mol/L;盐酸浓度范围为0.008~0.012mol/L.
We have set forth the designation and assemblage of plate columns absorption experiment, defined the normal operation conditions, The results show that the optimal conditions for the experiment are: the fluid flow rate: 1.17×10 -5 m 3/h; the air flow rate: 353~488 m 3/h; concentration of NH 3·H 2O: 0.076~0.12 mol/L; concentration of HCl 0.008~0.012 mol/L.
出处
《辽宁大学学报(自然科学版)》
CAS
2000年第1期19-22,共4页
Journal of Liaoning University:Natural Sciences Edition
关键词
板式塔
性能测试
吸收实验
plate columns, absorption, function test.