摘要 目的:评估SPECT测定不同年龄段健康人肾小球滤过率(GFR)的准确性。方法:以232例北京地区社区健康居民为研究对象,分别采用双血浆法和99Tcm-二亚乙基三胺五乙酸(99Tcm-DTPA)肾动态显像法测定肾GFR(GFRdt和GFRGates)。以GFRdt为参照标准,分析比较SPECT测定20~29岁、30~39岁、40~49岁、50~59岁、60~69岁及>70岁的6个不同年龄组健康人肾小球率过滤的准确性。结果:①6个不同年龄组所得GFRGates与GFRdt均具有显著性差异。②6个不同年龄组所得GFRGates均明显低于GFRdt,其中30~39岁年龄段GFRGates与GFRdt的差异最大,差异均值为(-34.26±20.79);>70岁年龄组GFRGates与GFRdt的差异最小,差异均值为(-9.48±10.85)。③30~39岁组GFRGates与GFRdt相关性(r=0.42)最差;>70岁组GFRGates与GFRdt相关性(r=0.81)最好。结论:SPECT测定20~49岁健康人GFR的准确性较差,测定≥50岁健康人GFR的准确性较好,其中≥70组准确性最好。 Objective: To estimate the accuracy of SPECT determination glomerular filtration rate in different age healthy groups. Methods: Totally 232 Beijingcommunity health residents were selected as the research subjects. Two-sample method and "Tc'"-DTPA dynamic renal imaging were usea Ior determination of GFR (GFRdt and GFR6ates, respectively). GFRdt as the reference standard, compare the accuracy of six different age groups GFR^ate~ which get by SPECT. Results: ~There were significant differences between GFRdt and GFRGat~ on six different age groups. ~GFRG,,~ from Six different age groups were significantly lower than those of GFRdt. The difference in the group of 50-59years between GFRdt and GFRGat~ is maximum, the mean difference is (-54.26_-_20.79) ml/(mino 1.75m)2. The difference in the group of _〉70years between GFRat and GFR6ates is minimum, the mean difference is (-25.62_+ 18.60) ml/(min* 1.75m)2. ~GFRdt and GFR6,tes derived from the group 50-39years had the worst correlation (r=0.42). GFRdt and GFR^ate~ derived from the group -~70years had the best correlation (r=0.81). Conclusion: The accuracy of GFR which got by SPECT is poor in 20-49years health group, it is better in _〉50 Years health group, while it is the best in 〉-70 years health group.
出处 《中国医学装备》 2013年第6期5-8,共4页 China Medical Equipment
基金 国家973项目(2013CB530800)"内脏器官衰老与相关老年疾病防治的基础研究"
关键词 肾小球滤过率 放射性核素显像法 双血浆法 健康人 准确性 Glomerular filtration rate Radionuclide imaging method Dual plasma sample method Health people Accuracy
  • 相关文献

参考文献15

  • 1Dias AH,Pintao S,Almeida P,et al.Comlmrison of GFR calculation methods: MDRD and CKD- EPI vs. 99mTc-DTPA tracer clearance rates[J]. Scand J Clin Lab Invest,2013,[Epub ahead of print].
  • 2Gore JL,Singer /S,Brown AF,et al.The socioeconomic status of donors and recipients of living unrelated renal transplants in the United States[J]. J U rol, 2012,187(5) : 1760-1765.
  • 3Srinivas S,Annigefi RA,Mani MK,et al.Eaimation of glomerular filtration rate in South Asian healthy adult kidney donors[J].Nephrology(earlt on), 2008,13(5): 440-446.
  • 4杨吉刚,李春林,邹兰芳,张楠.^99mTc—DTPA肾动态显像法测定健康人GFR的研究[J].医学临床研究,2011,28(7):1233-1235. 被引量:7
  • 5薛建军,杨爱民,邓惠兴,高蕊,冉宏德,程虎.^(99m)Tc-DTPA测定肾小球滤过率在移植肾活体供体中的应用价值[J].现代泌尿外科杂志,2010,15(4):263-266. 被引量:6
  • 6Zhao X,Shao Y,Wang Y,et ahNew normal values not related to age and sex, of glomerular filtration rate by (99m)Tc-DTPA renal dynamic imaging, for the evaluation of living kidney graft donors[J].Hell J Nucl Meal,2012,15(3):210- 214.
  • 7Ligthart GJ, Corberand JX,Geertzen HG,et al.Necessity of the assessment of health status in human immunogerontological studies: evaluation of the SENIEUR protocol[J].Mech Ageing Dev, 1990,55(1) :89-105.
  • 8Du Bois D,Du Bois EF.A formula to estimate the approximate surface area if height and weight are known[J]. Nutrition, 1989,5(5). 303-311.
  • 9麻广宇,邵明哲,陈云爽,徐白萱,陈英茂,田嘉禾,孙雪峰.肾脏深度对SPECT测定肾小球滤过率的影响[J].中国医学影像技术,2013,29(5):800-804. 被引量:10
  • 10Chantler C,Barratt TM.Estimation of glomerular filtration rate from plasma clearance of 51-chromium edetic acid[J].Arch Dis Child, 1972,47(254).613-617.

二级参考文献64

共引文献72

同被引文献25

  • 1李乾,张春丽,王荣福.肾动态显像测定肾小球滤过率的影响因素[J].中国医学影像技术,2004,20(6):962-964. 被引量:34
  • 2周玉红,左力,王梅,马迎春,张春丽,王荣福,王海燕.单血浆法与双血浆法^(99)Tc^m-DTPA血浆清除率的比较[J].中华核医学杂志,2005,25(4):234-236. 被引量:4
  • 3RUSSELL CD. Optimum sample times for single-injection, mul- tisample renal clearance methods [ J ]. J Nuel Med, 1993, 34 : 1761-1765.
  • 4HAM HR, PIEPSZ A. Clinical measurement o renal clearance [J]. Curr Opin Nephrol Hyfertens, 1992,1 : 252-260.
  • 5DURAND E, PRIGENT A. The basics of renal imaging andfunction studies[J]. Q J Nucl Med. 2002,46:249-267.
  • 6ELEMING JS, WILLKINSON J. Comparison of radionuclide es- timation ation of gliomerular filtration rate using lecthnetium 99m diethylenetraim inepentaacetic acid and chromium 51 ethyl- enediam inetetraacetic acid[J]. Eur J Nucl Med, 1991,18: 391- 395.
  • 7PETERSEN LJ, PETERSEN JR, TALLERUPHUUS U, et al. Glomerular filtration rate estimated from the uptake phase of 99mTC-DTPA renography in chronic renal failure[J]. Nephrol Dial Transplant, 1999,14 : 1573-1678.
  • 8BLAUFOX MD, AURELL M, BUBECK B, et al. Report of the radionuclides in nephrourology committee on renal clearance[J]. J Nucl Med, 1996, 37(11): 1883-1890.
  • 9PIEPSZ A, DOBBELEIR A, ERBSMANN F. Measurement of separate kidney clearance by means of gmTc-DTPA complex and a scintillation camera[J]. Eur J Nucl Med, 1977, 2:173-177.
  • 10GATES GF. Glomerrular filtration rate., estimation from frac- tional renal accumulation of 99 mTc-DTPA[J]. AJR AmJ Roent- gnol, 1982,138 : 565-570.

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部