摘要
以某火力发电厂为例,对一次汽轮机主保护动态传动过程中出现较长延时的情况进行分析,确定了异常的原因,采取了相应的措施,以避免类似事件再次发生。
A longer delay occurred during the dynamic transmission process of the steam turbine master protection of a thermal power plant.The abnormal situation was analyzed,and the reason of the anomaly was determined.The corresponding measures were adopted,and similar incident is avoided.
出处
《华电技术》
CAS
2013年第5期54-55,78,共2页
HUADIAN TECHNOLOGY
关键词
汽轮机主保护
延时跳闸
异常分析
措施
master protection of seam turbine
delay of tripping
analysis of anomaly
measure