围海水电站机组技术供水系统的缺陷分析及处理 被引量:1

Analysis on defects of technical water supply system of hydroelectric generating set in Weihai Hydropower Station and treatment
下载PDF
导出
摘要 围海水电站水轮发电机组技术供水温度过高,在夏季对水轮发电机组各轴承冷却效果不佳,各轴承的瓦温、油温、空气冷却器风温都达到报警值并接近停机温度,对机组的安全、稳定运行产生了严重的威胁,分析了故障的原因并作了消缺处理后,改善了冷却效果,清除了机组隐患。 In Weihai Hydropower Station,the temperature of the technical supplied water for the hydroelectric generating set wastoo high,and at summer,the cooling effects for the bearings of the hydroelectric generating set were poor.The bearing bush temperature and the oil temperature of the bearings and the air temperature of the air cooler all achieved the alarm value and were close to the temperature for emergency stop,which threatens the unit safe and stable operation seriously.The fault and the reasons of the problems were analyzed,and the defect eliminating measures were adopted.The fault does not appear again.
作者 邓成洪
出处 《华电技术》 CAS 2013年第5期56-57,78-79,共2页 HUADIAN TECHNOLOGY
关键词 技术供水 循环 原因分析 处理方法 technical water supply circulation reason analysis treatment method