摘要
为实现电力系统 OPF 最优无功功率潮流控制计算、无功功率补偿规划、运行分析和电力市场中的无功考核指标,在电力系统 OPF 的最优无功研究中引入经济压差 ΔUJ 算法,将大规模电力系统的无功功率优化计算分解成按电压等级的分层计算。
In order to implement calculation of optimal reactive power; reactive power compensation planning; operation analysis and reactive power index in electric power market, economic voltage difference ΔUJ algorithm is introduced in optimal reactive power studies. ΔUJ algorithm makes the optimal reactive power calculation for large power system divide the hierarchy calculation according to voltage level.
出处
《中国电力》
EI
CSCD
北大核心
2000年第9期42-44,共3页
Electric Power