提出利用三相电压采样值计算频率的“虚拟电枢磁势”法。此方法构想了一种“虚拟电机”,以它的“电枢磁势”的旋转角速度作为节点的动态频率。此方法在计算过程中,能够滤除零序分量;在结合自适应调整采样周期方法之后,又消除了整次谐波和负序分量对测量频率的影响,跨越了繁琐复杂的滤波和滤序的过程,快速精确地测算了真实的电力系统实时频率。
The paper presents a method of 'virtual armature magnetic flux' by using the sampling value of three-phase voltage. In this method, the rotating angular velocity of the 'virtual armature magnetic flux' is taken as the dynamic fre- quency of the node. This calculation can eliminate the influence of negative-sequence, zerosequence and harmonic signals, thus it is fast and accurate to obtain the true frequency of the power system.