摘要
阐述双断口磁场断路器配高能氧化锌非线性电阻灭磁系统的工作原理、成功灭磁所必须具备的条件;以葛洲坝6号机组灭磁系统为例,分析该灭磁系统存在的问题,并就此提出一些改进建议。
This article describes the working principle of the dual-pole field breaker with high energy nonlinear ZnO resistor and the essential conditions for successful deexcitation. Taking the No.6 generating unit of Gezhouba Hydropower Station as example, this article analyzes the existing perplexities of the de-excitation system, and presents some improving proposals.
出处
《中国电力》
CSCD
北大核心
2000年第8期38-40,共3页
Electric Power
关键词
磁场断路器
灭磁
电流转移
氧化锌非线性电阻
field breaker
nonlinear resistor
de-excitation
break voltage
current transfer