摘要
根据设备结构情况分析了大机组锅炉回转式空气预热器的漏风 ,并加以试验和调整。通过热态运行检验 ,使漏风控制达到了设计标准 ,为提高锅炉经济效率打下良好基础。
The wind leakage of revolving-type air preheater of large generating-set boilers are analysed according to the structure of equipments,and the test and regulation had been carried out.The wind leakage control has reached the standard of design,verified by heat state operation;and gets a well base to enhance the boiler economic efficiency.
出处
《东北电力技术》
2000年第8期2-5,共4页
Northeast Electric Power Technology
关键词
回转式空气预热器
漏风控制
锅炉