期刊文献+

Vibration of 1000-MW Ultra-Supercritical Turbine-Generator Unit with Simens Technology

Vibration of 1000-MW Ultra-Supercritical Turbine-Generator Unit with Simens Technology
下载PDF
导出
摘要 The layout features of unit shafting and their effects on vibration, as well as evaluation criteria, were introduced for a 1000-MW ultra-supercritical turbine-generator unit with Simens technology. Based on vibration diagnosis and treatment for more than 10 units, some typical vibration faults were summarized, such as the vibration fluctuation of the high pressure (HP) rotor, abnormal vibration increases of the No.3 bearing pedestal and large vibration of the exciter rotor during its critical speed range. The vibration characteristics and the causes of faults and countermeasures were analyzed. Three applications for further illustration were given. The vibration fault identification method, control measures, and applications can provide a reference for vibration diagnoses and treatment of same type units. The layout features of unit shafting and their effects on vibration, as well as evaluation criteria, were introduced for a 1 000-MW ultra-supercritical turbine-generator unit with Simens technology. Based on vibration diagnosis and treatment for more than 10 units, some typical vibration faults were summarized, such as the vibration fluctuation of the high pressure (HP) rotor, abnormal vibration increases of the No.3 bearing pedestal and large vibration of the exciter rotor during its critical speed range. The vibration characteristics and the causes of faults and countermeasures were analyzed. Three applications for further illustration were given. The vibration fault identification method, control measures, and applications can provide a reference for vibration diagnoses and treatment of same type units.
出处 《Electricity》 2012年第5期48-54,58,共8页 电气(英文版)
关键词 汽轮发电机组 轴系振动 西门子技术 超超临界 励磁机转子 振动故障 应用程序 振动诊断 1 000-MW ultra-supercritical unit vibration single bearing support rotor (thermal) unbalance rotor dynamic (thermal) balance
  • 相关文献

参考文献5

  • 1Zhang X Y. Vibration diagnosis for steam turbine generator unit [M]. Beijing: China Electric Power Press, 2008.
  • 2Xi'an Thermal Power Research Institute Co., Ltd. Vibration test and characteristics analysis for 1 000- MW ultra-supercritical turbine-generator unit with SIMENS technology [R], 2010.
  • 3Xi'an Thermal Power Research Institute Co., Ltd. The No.3 unit vibration fault diagnosis and treatment for Huaneng Yuhuan power plant [R]. 2010.
  • 4Jongh F M. The synchronous rotor instability phenom- enon-morton effect [C]// Proceedings of the Thirty- Seventh Turbomachinery Symposium, 2008:159-167.
  • 5Phuttipongsit A. The Morton Effect and light rubs in rotating machinery [J]. ORBIT Magazine, 2007, 27(1): 45-51.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部