为保护地下水资源,工业项目建设过程中需要制定出合理的地下水污染监控方案。特别是在地下水系统比较脆弱的低丘区,其松散层发育较薄,极易造成地下水污染。以某工场项目为例,利用水质模拟模型,模拟出该项目在非正常工况下可能污染物下渗到地下水系统中的运移扩散规律,并根据模拟结果制定出合理的观测井布设方案和监测频率。
In order to protect groundwater resources, the reasonable monitoring program of groundwater contamination was formulated in industrial project construction especially in low hill area with unconsolidated layer which is vulnerable of groundwater system. Taking a workshop project as an example, contaminant's movement and diffusion in the groundwater system were simulated under abnormal working condition by water quality simulation model. The reasonable layout scheme and monitoring frequency of monitoring well were formulated according to the simulation results.
出处
《供水技术》
2013年第3期1-5,共5页
Water Technology
关键词
潜水
污染
监测井
监测频率
phreatic water
contamination
monitoring well
monitoring frequency