单相电子式电能表测量结果不确定度评定

Evaluation of Uncertainty in Measurement Result of Error for Single Phase Electrical Energy Meters with Electronics
下载PDF
导出
摘要 依据JJG596-1999《电子式电能表检定规程》,对重复测量引起的不确定度采用A类,对标准表溯源、标准表的年稳定度、标准表和被检表电压端电位差、功率源稳定度对测量结果的影响等引起的不确定度采用B类评定方法,通过合成标准不确定度,最终计算出扩展不确定度。 Based on JJG596-1999 "Electronic Energy Meter Testing Procedures", this paper applied Class A method to evaluate the uncertainty caused by repeated measurements, and used Class B method to evaluate the uncertainty caused by traceable to standard tables, year stability of standard tables, the voltage terminal potential difference of standard table and seized table, power source stability, and finally calculated the expanded uncertainty by the combined standard uncertainty.
出处 《价值工程》 2013年第18期322-323,共2页 Value Engineering
关键词 电能 测量结果 不确定度 electric energy measurement uncertainty
  • 相关文献

参考文献3

  • 1JJG596-1999,电子式电能表检定规程[S].北京:中国计量出版社,1999.
  • 2JJF1059-1999,测量不确定度评定与表示[S].北京中国计量出版社,1999.
  • 3JJG597-2005,交流电能表检定装置检定规程[S].北京:中国计量出版社,2005.