摘要
结合国家核安全局法规和导则规定,介绍了设备承包商和工程总承包公司对不符合项的处理情况,最后就田湾核电站1、2号机组建造过程中遇到的"立管弹簧支架管夹变形"这一重大不符合项的处理过程进行了回顾,分享了笔者的一些体会。
Combined with the guidelines & rules of national nuclear safety administration,introduced treating with problem of not correspond requirements of equipment by the equipment-supply contractor and the project main contract company, then reviews the dispose process of the important not correspond requirements of "stand pipe-spring support mingles'deformation" in the set No.1 and 2 of Tianwan nuclear power plant, introduced some experiences.
出处
《工程质量》
2013年第6期31-34,共4页
Construction Quality
关键词
核安全
物项
不符合项
工程总承包公司
许可证条件
nuclear safety
contents
not correspond requirements
the PMC company
the conditions of license