氨纶中抗氧剂1790的高效液相色谱检测法 被引量:3

Determination of antioxidant 1790 in spandex by high performance liquid chromatography
下载PDF
导出
摘要 探讨了用高效液相色谱法测定氨纶中抗氧剂1790的方法.采用Agilent Zorbax SB-C18(4.6mm×250mm,5μm)色谱柱,V(甲醇):V(水)=90:10作为流动相,在流速为0.7mL/min、波长为274nm的检测条件下,抗氧剂1790在0.26-10.4mg/mL内线性关系良好,检出限为0.076mg/mL.该方法操作简便,分析速度快,重复性好. A method for the determination of antioxidant 1790 in spandex by HPLC was discussed. The determination conditions were as follows: C18 column (Agilent Zorbax SB-C18, 4.6 mm×250 mm, 5 μm), UV detector at 274 nm, the mobile phase was V(methanol):V(water)=90:10, the flow rate was 0.7 mL/min. Lineari- ty of antioxidant 1790 regression equation was achieved on the range of 0.26-10.4 mg/mL The detection lim- its was 0.076 mg/mL. The method was simple, rapid and reproducible.
作者 张洛红 冯琳
出处 《印染助剂》 CAS 北大核心 2013年第6期47-49,共3页 Textile Auxiliaries
基金 西安工程大学博士科研启动金(BS0715) 留学回国人员科研启动基金[教外司留(2010)1561号]
关键词 氨纶 抗氧剂1 790 高效液相色谱 spandex antioxidant 1790 HPLC