期刊文献+

炼油及乙烯装置废碱液湿式氧化处理工艺的研究 被引量:17

WET AIR OXIDATION TREATMENT OF WASTE CAUSTIC LIQUOR FROM REFINERY AND ETHYLENE PLANT
下载PDF
导出
摘要 根据炼油及乙烯装置废碱液的性质 ,提出了空气湿式氧化处理工艺并就其过程中反应温度和停留时间对S2 -、COD、挥发酚氧化性的影响在实验室小型试验装置上进行了研究 ,结果表明 :S2 -容易脱除 ,在 15 0℃以下转化为S2 O32 -,在 180℃以上转化为SO4 2 -;在 15 0℃以下COD去除率较低 ,温度对COD的去除影响很小 ,在 15 0℃以上 ,随反应温度的提高COD去除率显著增加 ;酚的氧化主要发生在 15 0℃以上 ,在 12 0~ 15 0℃的范围内 ,酚的氧化率只有 6 %~ 7% Based on the characteristics of waste caustic liquor generated from refineries and ethylene plants, the influence of reaction temperature and retention time of a wet air oxidation system on the oxidation of S 2- , COD and phenol were conducted in the laboratory. The results showed that S 2- was removed easily and oxidized into S 2O 3 2- and SO 4 2- below 150 ℃ and above 180 ℃ respectively. The COD removal was low at a temperature less than 150 ℃ and nearly not affected by temperature. Conversely, the COD removal was obviously increased with temperature raise at a temperature higher than 150 ℃. Phenol was oxidized mainly at a temperature higher than 150 ℃, its oxidation rate was only 6%~7% in the temperature range of 120~150 ℃.
作者 郭宏山
出处 《石油炼制与化工》 CAS CSCD 北大核心 2000年第10期39-43,共5页 Petroleum Processing and Petrochemicals
关键词 脱硫 炼油 乙烯 废碱液 废水处理 湿式氧化 air oxidation waste liquor treatment wet desulfurization temperature resident time.
  • 相关文献

同被引文献154

引证文献17

二级引证文献81

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部