摘要 目的与传统滤波反投影(FBP)重建比较,评价Flash双源CT基于原始数据的正弦图确定迭代重建(SAFIRE)在冠状动脉支架中的应用价值。方法对54例患者冠状动脉支架术后行DSCT冠状动脉成像,比较FBP、SAFIRE(1~5)重建6组图像的平均CT值、SNR、支架内CT值净增比(SAIR)、图像质量主观评分、支架显示情况等。结果主动脉根部、支架内、支架上方冠状动脉的平均CT值差异均无统计学意义(P均>0.05)。SAIR、SNR差异有统计学意义(P均<0.05),FBP重建SAIR值最大,SAFIRE 3重建SAIR值最小;SAFIRE 3的SNR值最大。FBP与SAFIRE重建图像质量主观评分差异有统计学意义(P<0.05),SAFIRE 3主观评分最高[(3.24±0.57)分]。FBP与SAFIRE重建对于病灶的显示情况基本一致。结论与传统的FBP重建比较,SAFIRE重建可明显降低冠状动脉支架图像噪声,改善图像质量,更清晰显示支架内斑块。SAFIRE强度采用机器默认的重建强度3图像质量最佳。 Objective To assess the application value of sinogram affirmed iterative reconstruction (SAFIRE) in coronary artery stents with cardiac CT angiography by comparison with filtered back projection (FBP). Methods Fifty-four patients with implanted stents underwent Flash CT, and six groups of images were reconstructed with FBP and SAFIRE (reconstruction strength 1-5). The mean CT values, SNR, stent-lumen attenuation increase ratio (SAIR), image quality scores and display of stents were compared. Results CT values of aortic root,in-stent, the coronary artery above stent had no significant difference (all P〈0. 05). SAIR and SNR were statistically different (both P〈0. 05). SAIR was the largest with FBP and the smallest with SAFIRE 3, while the largest SNR and the highest image quality (3.24~0.57) were obtained with SAFIRE 3. There was statistical difference in image quality scores between FBP and SAFIRE (P(0.05). Display of lesion of FBP and SAFIRE were in general accord. Conclusion SAFIRE can significantly reduce SNR, improve imaging quality of coronary artery stents, and display plaque in the stent by Flash CT compared with FBP . Reconstruction strength 3 of SAFIRE may be recommended to reconstruct excellent images.
出处 《中国医学影像技术》 CSCD 北大核心 2013年第6期1023-1027,共5页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 冠状血管 支架 迭代重建 滤波反投影 Tomography, X-ray computed Coronary vessels Stents Iterative reconstruction Filtered back projection
  • 相关文献

参考文献12

  • 1Renker M, Nance JW Jr, Schoepf UJ, et al. Evaluation of heavi-ly calcified vessels with coronary CT angiography: Comparison ofiterative and filtered back projection image reconstruction. Radiol-ogy, 2011,260(2):390-399.
  • 2Price RR, Axel L, Morgan T, et al. Quality assurance methodsand phantoms for magnetic resonance imaging: Report of AAPMnuclear magnetic resonance Task Group No. 1. Med Phys, 1990,17(2):287-295.
  • 3Yang WJ, Pan ZL, Zhang H, et al. Evaluation of coronary arteryin-stent restenosis with prospectiveiy ECG-triggered axial CT an-giography versus retrospective technique: A phantom study. Ra-diol Med, 2011,116(2):189-196.
  • 4Herzog BA, Husmann L, Burkhard N, et al. Low-dose CT coro-nary angiography using prospective ECG-triggering : Impact ofmean heart rate and heart rate variability on image quality. AcadRadiol, 2009,16(1):15-21.
  • 5阙介民,王燕芳,孙翠丽,魏存峰,史戎坚,魏龙.基于不完备投影数据重建的四种迭代算法比较研究[J].CT理论与应用研究(中英文),2012,21(2):169-178. 被引量:23
  • 6Gosling .,Loader R, Venables P, et al. A comparison of radia-tion doses between state-of-the-art multislice CT coronary angiog-raphy with iterative reconstruction, multislice CT coronary angi-ography with standard filtered back-projection and invasive diag-nostic coronary angiography. Heart, 2010, 96(12) :922-926.
  • 7Prakash P, Kalra MK,Ackman JB, et al. Diffuse lung disease:CT of the chest with adaptive statistical iterative reconstructiontechnique. Radiology, 2010,256(1) :261-269.
  • 8Moscariello A, Takx RA, Schoepf UJ, et al. Coronary CT angi-ography :Image quality, diagnostic accuracy, and potential for ra-diation dose reduction using a novel iterative image reconstructiontechnique-comparison with traditional filtered back projection.Eur Radiol, 2011,21(10):2130-2138.
  • 9Han BK, Grant KL, Garberich R, et al. Assessment of an itera-tive Reconstruction algorithm (SAFIRE) on image quality in pedi-atric cardiac CT datasets. J Cardiovasc Comput Tomogr, 2012,6(3):200-204.
  • 10Ebersberger U,Tricarico F, Schoepf UJ, et al. CT evaluationof coronary artery stents with iterative image reconstruction :Improvements in image quality and potential for radiation dosereduction. Eur Radiol, 2013,23(1) : 125-132.

二级参考文献17

  • 1张全红,路宏年,杨民,傅健.用对称反投影及递归迭代实现扇束CT快速重建[J].CT理论与应用研究(中英文),2004,13(4):16-19. 被引量:9
  • 2高河伟,张丽,陈志强,程建平.有限角度CT图像重建算法综述[J].CT理论与应用研究(中英文),2006,15(1):46-50. 被引量:15
  • 3Boone JM, Nelson TR, Lindfors KK, et al. Dedicated breast CT: Radiation dose and image quality evaluation[J]. Radiology, 2001, 221(3): 657-667.
  • 4Kaczmarz S. Angengherte auflSsung von systemen linearer gleichungen[J]. Bulletin International de l'Acadmie Polonaise des Sciences et des Lettres. Classe des Sciences Math4matiques et Naturelles. Sarie A, Sciences Mathmatiques, 1937, 35: 355-357.
  • 5Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data[J]. IEEE Transaction on Medical Imaging. 1994, 13(4): 601-609.
  • 6Schmidlin P, Matthias EB, Gunnar B. Subsets and overlaXation in iterative image reconstruction[J]. Physics in Medicine and Biology, 1999, 44(5): 1384-1396.
  • 7Sidky EY, Kao CM, Pan XC. Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT[J]. Journal of X-Ray Science and Technology, 2006, (14): 119-139.
  • 8Bouman CA. A unified approach to statistical tomography using coordinate descent optimization IEEE Trans[J]. Image Processing, 1996, 5(3): 480-492.
  • 9Bouman CA, Sauer K. A generalized Gaussian image model for edge-preserving MAP estimation, IEEE Trans[J]. Image Processing, 1993, 7(2): 296-310.
  • 10N. Hirai,J. Horiguchi,C. Fujioka,M. Kiguchi,H. Yamamoto,N.Matsuura,邱建星(译),唐光健(校).前瞻性和回顾性心电门控64层CT冠状动脉成像影像质量,血管狭窄和放射剂量评估的对照性研究[J].国际医学放射学杂志,2008,31(5):399-400. 被引量:81

共引文献37

同被引文献55

  • 1周玉杰,贾德安.批阅三载 增删十次——《冠状动脉粥样硬化性心脏病诊断标准》诞生记[J].中国卫生标准管理,2010,1(4):20-21. 被引量:36
  • 2刘新,李颖,杨立,赵锡海,王新疆,赵绍宏,张玉霄,蔡祖龙.64层螺旋CT评价冠状动脉支架内再狭窄的价值[J].中华放射学杂志,2006,40(8):808-811. 被引量:44
  • 3Renker M, Nance JW, Schoepf UJ, et al. Evaluation of heavilycalcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction. Radiology, 2011, 260(2): 390-399.
  • 4Ebersberger U, Tricarico F, Schoepf U J, et al, CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction. Eur Radiol, 2013, 23(1): 125-132.
  • 5Gosling O, Loader R, Venables P, et al. A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography. Heart, 2010, 96(12): 922-926.
  • 6Moscariello A, Takx RA, Schoepf U J, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. Eur Radiol, 2011, 21(10): 2130-2138.
  • 7Hart BK, Grant KL, Garberich R, et al. Assessment of an iterative reconstruction algorithm (SAFIRE) on image quality in pediatric cardiac CT datasets. J Cardiovasc Comput Tomogr, 2012, 6(3): 200-204.
  • 8Price RR, Axel L, Morgan T, et al. Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1. Med Phys, 1990, 17(2): 287-295.
  • 9Yang WJ, Pan ZL, Zhang H, et al. Evaluation of coronary artery in-stent restenosis with prospectively ECG-triggered axial CT angiography versus retrospective technique: a phantom study. Radiol Med, 2011, 116(2): 189-196.
  • 10Herzog BA, Husmann L, Burkhard N, et al. Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality. Acad Radiol, 2009, 16(1): 15-21.

引证文献6

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部