丹江电厂工频高压电场工作人员健康调查 被引量:5

Health Survey on Workers Working in Surroundings of the Work Frequency and Electric Field of High Tension in Danjiang Hydropower Station
下载PDF
导出
摘要 丹江电厂已建成运行 30周年 ,其变配输电采用 5 0Hz 2 2 0kV、 1 1 0kV和 2 0kV三种电压。2 2 0kV输电线路最高电场强度 0 4kV/m ,磁感应强度 1 4mG (1 4× 1 0 -3 mT) ;1 1 0kV输电线路最高电场强度 0 2kV/m ,磁感应强度 6mG (6× 1 0 -4 mT) ;2 0kV输电线路最高电场强度 0 0 8kV/m ,磁感应强度1 9mG (1 9× 1 0 -4 mT)。变配电设备周围最高场强 (2 2 0kV) 5kV/m ,磁感应强度 1 0~ 80mG (1× 1 0 -3~ 8× 1 0 -3 mT)。该环境中工作人员自觉症状与对照组有显著性差异 ,而临床测试和实验室检查未发现与对照组存在显著性差异。由此提示该工频电场环境可引起正常作业人体一些自觉症状 ,但健康检测数值没有超出允许值范围。 Danjiang Hydrpower Station has been running for 30 years,transforming,distributing and sending electricity of 50 Hz 220 kV,110 kV and 20 kV.The highest electric field intensity(220kV)of the electric line of transmission is 0 4 kV/m and the magnetic induction intensity is 14 mG(1 4×10 -3 mT).The highest electric field intensity(110 kV) of the electric line of transmission is 0 2 kV/m and the magnetic induction intensity is 6 mG(6×10 -4 mT).The highest electric field intensity (20 kV)of electric line of transmission is 0 08 kV/m and the magnetic induction intensity is 1 9 mG(1 9×10 -4 mT).The highest electric field intensity around the electricity transformation and distribution equipment(220 kV)is 5 kV/m and the magnetic induction intensity is 10~80 mG(1×10 -3 ~8×10 -3 mT).The workers working in above surroundings have more subjective symptoms than those of controls,but no obvious difference has been found between these two groups when they are given clinical examination and lab tests.So,it could be concluded that some subjective symptoms may be induced for workers working in this surroundings,however,the findings of physical examination do not exceed the normal value.
出处 《工业卫生与职业病》 CAS CSCD 2000年第2期78-81,共4页 Industrial Health and Occupational Diseases
关键词 丹江电厂 工频高压电场 健康调查 工作人员 Danjiang Hydropower Staion Work frequency and high tension electric field Health survey
  • 相关文献

参考文献1

共引文献12

同被引文献21

  • 1邬雄,蒋虹,何芹.工频电场及安全问题[J].安全与电磁兼容,1996(4):28-30. 被引量:6
  • 2Van Trees H L. Detection, Estimation, and Modulation Theory, Part III[M]. New York: John Willy and Sons, Inc, 2001: 415-419.
  • 3Digalakis V, Rohlicek J, and Ostendorf M. ML estimation of a stochastic linear system with the EM algorithm and its application to speech recognition[J]. IEEE Transactions on Speech Audio Processing, 1993, 1(4): 431-442.
  • 4Shumway R H and Stoffer D S. An approach to time series smoothing and forecasting using the EM algorithm[J]. Journal of Time Series Analysis, 1982, 3(4): 253-264.
  • 5国际大电网会议第36.01工作组著.输电系统产生的电场和磁场[M].北京:水利电力出版社,1984.
  • 6Fefdorowski A. Electromagnetic as a health risk factor sources of artificial EMFs, evaluation of health risk, prevention mehtods[J]. Med-Pr, 1997,48(5): 507-519.
  • 7Conti R, Pi ini A, Giorgi A, et al. Evaluation of possible impacts of the new limits for human exposure to magnetic fields under consideration in Italy[C]. CIGRE, Paris, 2002: 36-106.
  • 8Carlos G. Low-frequency magnetic fields from electrical appliances and powerlines[J]. IEEE Trans on Power Delivery, 2003, 18(4): 1310-1319.
  • 9Daily W K. Measurements and computation of EMF in electric power substations[J]. IEEE Trans on Power Delivery, 1994, 9(1): 324-333.
  • 10Isokorpi J. Power frequency electric fields at a 400 kV substation[C].1999-ISH. Landon, UK, 1999: 2.107. P6-2.111.P7.

引证文献5

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部