期刊文献+

新型量子光电探测器读出与显示

A New Quantum Photodetector Array Readout and Display
下载PDF
导出
摘要 对一种响应近红外的新型量子光电探测器特性进行测试和分析,给出了2×8探测器阵列和读出电路的对接测试结果,设计初步的成像系统采集显示焦平面输出。探测器有一个-0.8V的阈值电压,偏压大于阈值电压后器件响应率远大于1A/W,且响应率随光照功率增大减小。2×8探测器阵列与设计的读出电路通过Si基板对接后在77K条件测试,读出电路的线性度好于99.5%,信噪比达到67dB,探测器偏压为-1.5V,积分时间为200μs时探测器率达到1.38×1010cmHz1/2/W,达到实际应用的要求。设计了数据采集卡和成像系统验证了对接样品的实用性。 A novel quantum photodetector response near infrared wavelength was presented and tested, a 2 × 8 detector amay prototype coupled with readout circuit integrated circult(R.OIC)was described and discussed in this paper, and principium imaging system was designed and presented at last.There is a threshold voltage of -0.8V of the detector, when bias voltage greater then threshold voltage responsibility bigger then 1A/W and decrease as light power increased.According to the unique characteristic of the detector, specialized readout circuit was designed and coupled with a 2 × 8 test prototype detector array.Measurement results of the detector and readout circuit have successfully verified at 77K.Linearity of the readout circuit is better than 99.5%.Signal to noise ratio achieves 67dB.The detectivity of the coupled prototype was estimated to be 1.38× 10^10cmHzl/2/W when detector was bias at -1.5V and integratiort time is 200μs, which meet the practical application demands.A validated data acquisition card and imaging system were designed and demonstrated to verify the coupled sample.
作者 郑磊
出处 《电子世界》 2013年第13期43-44,共2页 Electronics World
关键词 量子光电探测器 读出电路 噪声 信噪比 探测率 quantum photodetector readout circuit noise signal to noise ratio detectivity