导出
摘要 目的 寻求检查非骨水泥全髋置换 (THR CL)手术前后骨密度 (BMD)变化的最佳方法。方法 采用双能X线骨密度仪 (DEXA)与常规X线摄片对 7例手术前、后以及术后 1~ 3年内的近段股骨各兴趣区BMD进行检测和比较。结果 DEXA定量显示 1、5、6区术后BMD增加 ,其中 1区增加显著 (10 42 % ) ,2、3、4、7区减少 ,其中 7区减少显著 (16 5 % )。术后 1年内BMD在 6、7区呈持续显著减低 4 4%~ 5 6 % ,在 3、4、5区呈持续显著增高 6 2 %~ 6 6 % ,而 1、2区仅轻微减少1 3%~ 1 8% ,术后 2~ 3年BMD改变轻微。相比之下 ,手术前、后X线摄片均未能显示任何BMD差异 ,更未能定量显示。结论 DEXA具有辐射量低、敏感性强、重复检查误差小和定量正确性高等优点。手术前、后各区BMD变化对评价THR CL股骨头假体固定质量的意义。 Objective To get the technique for the measurement of bone mineral density(BMD) in defined areas around metal implants.Methods Seven cses of BMD in the regions of proximal femora adjacent to metal cementless femoral implants before and 1-3 years after the cementless total hip replacement(THR-CL) were determined and compared by means of dual-energy x-ray absorptiometry(DEXA) and radiography.Results It was shown that the BMD values increased immediately after operation at zones 1,5,and 6 with the maximum increase at zone 1(10 42%),but reduced immediately after operation at zones 2,3,4 and 7 with the maximum reduction at zone 7 (16 5%).One year after the operation,BMD was continuously decreasing at zones 6 and 7,but significantly increasing at zones 3,4 and 5.In the three years after that,BMD change in defined areas was only slightly seen.But x-ray films did not show any difference between the control and operated femora.Conclusion It is suggested that DEXA has the advantages of low radiation,high sensitivity,reproducible,and high precision.Therefore,it is much better than the clinicoe radiography.This paper also discussed the right procedures for the determination of BMD with DEXA,and the significance of BMD value of each region of interest around femoral components to judge the fixation quality for femoral components.
出处 《江苏医药》 CAS CSCD 2000年第8期612-614,共3页 Jiangsu Medical Journal
关键词 全髋关节置换术 双能X线骨密度仪 骨密度 Total hip replacement Dual-energy x-ray absorptiometry Bone mineral density
  • 相关文献

参考文献5

  • 1Svendsen OL,Hassager C,Skodt V,et al.Implant of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip and forearm[].Journal of Bone and Mineral Research.1995
  • 2Maloney WJ,Sychterz C,Bragdo C,et al.Skeletal response to well fixed femoral components inserted with and without cement[].Clinical Orthopaedics.1996
  • 3Nishii T,Sugano N,Masuhara K,et al.Longitudinal evaluation of time related bone remodeling after cementless total hip arthroplasty[].Clinical Orthopaedics.1997
  • 4Korovessis P,Piperos G,Michael A.Periprosthetic Bone Mineral Density After Mueller and Zweymuller Total Hip Arthroplasties[].Clinical Orthopaedics.1994
  • 5Kroger H,Miettinen H,Arnala I,et al.Evaluation of periprosthetic bone using dual-energy absorptiometry: Precision of the method and effect of operation on bone mineral density[].Journal of Bone and Mineral Research.1996

同被引文献12

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部