Indoor thermal comfort research on the hybrid system of radiant cooling and dedicated outdoor air system

Indoor thermal comfort research on the hybrid system of radiant cooling and dedicated outdoor air system
原文传递
导出
摘要 The radiant cooling system generally operates with the dedicated outdoor air system (DOAS). Air supply modes and the corresponding setting parameters of the hybrid system may substantially influence the indoor thermal comfort. With target indexes of air diffusion performance index (ADPI) and predicted mean vote (PMV), the Taguchi method was used to choose the optimal air supply mode and to analyze the significance of different factors on the thermal comfort. The results are expected for conducting the future design and regulation of the hybrid system. Computation fluid dynamics (CFD) simulation as well as verified experiments was performed during the research. Based on the ADPI studies, it is found that the air supply mode of ceiling delivery with ceiling exhaust is an optimized option to apply in DOAS of the hybrid system. Variance analysis results show that influence fact of air supply temperature is the most dominant one to impact the indoor thermal comfort index of PMV. The radiant cooling system generally operates with the dedicated outdoor air system (DOAS). Air supply modes and the corresponding setting parameters of the hybrid system may substantially influence the indoor thermal comfort. With target indexes of air diffusion performance index (ADPI) and predicted mean vote (PMV), the Taguchi method was used to choose the optimal air supply mode and to analyze the significance of different factors on the thermal comfort. The results are expected for conducting the future design and regulation of the hybrid system. Computation fluid dynamics (CFD) simulation as well as verified experiments was performed during the research. Based on the ADPI studies, it is found that the air supply mode of ceiling delivery with ceiling exhaust is an optimized option to apply in DOAS of the hybrid system. Variance analysis results show that influence fact of air supply temperature is the most dominant one to impact the indoor thermal comfort index of PMV.
出处 《Frontiers in Energy》 SCIE CSCD 2013年第2期155-160,共6页 能源前沿(英文版)
关键词 radiant cooling system dedicated outdoor airsystem (DOAS) thermal comfort Taguchi method var-iance analysis radiant cooling system dedicated outdoor airsystem (DOAS) thermal comfort Taguchi method var-iance analysis
  • 相关文献

参考文献2

二级参考文献19

  • 1孙斌,张旭.利用ADPI评价工作区有隔断的大空间建筑送风方式[A].上海市制冷学会2005年学术年会论文集[C].2008:381-384.
  • 2Dan Int-Hout. Air Distribution for Comfort and IAQ [ J ]. Heating Piping and Air Condition, 1998 (5) :90-92.
  • 3Elsafty, A. F. Ventilation Efficiency Inside a Ship Cabin Based on Air Diffusion Performance Index (ADPI) [ J]. European Journal of Scientific Research ,2010 (20) : 102-114.
  • 4GB/T5701-2008,室内热环境条件[S].
  • 5SDHRAE Standard 55, Thermal Environmental Conditions for Human Occupancy[ S]. ASHRAE,2004.
  • 6全国勘察设计注册工程师公用设备专业管理委员会秘书处.暖通空调专业考试复习教材[M].北京:中国计划出版社,2009.
  • 7GB/T18049-2000,中等热环境PMV和PPD指数测定及热舒适条件的规定[S].
  • 8Chen Qingyan, Moser A. Simulation of a multiple-nozzle diffuser. In: Proceedings of the 12th AIVC Conference on Air Movement and Ventilation Control within buildings, Canada: Ottawa, 1991, 2:1 - 13.
  • 9Nielsen P V. The selection of turbulence models for prediction of room airflow.ASHRAE Trans, 1998, 104(1): 1119 -1126.
  • 10Chen Qingyan, Xu Weiran. A zero-equation turbulence model for indoor air flow simulation. Energy and Buildings,1998, 28(1):137- 144.