期刊文献+

谷氨酸发酵废水电渗析脱盐 被引量:2

Desalination of Glutamate Fermentation Wastewater by Electrodialysis
原文传递
导出
摘要 采用普通电渗析脱除谷氨酸发酵废水中的无机盐,用活性炭对废水进行预处理,考察了预处理前后废水的电渗析性能.结果表明,活性炭用量为100和200g/L时,在60℃下处理30min,废水的脱色率分别达61%和75%.预处理前及100和200g/L活性炭预处理后乳酸迁移量依次降低,谷氨酸迁移率分别为24%,35%和39%,SO42迁移率分别为77%,80%和84%,NH4+迁移率分别为89%,86%和84%,膜堆电阻依次增加,SO42脱除率达85%时,能耗分别为4.88,3.93和3.64kWh'/kg. Electrodialysis was used to desalinate inorganic salts from a glutamic acid fermentation wastewater, and activated carbon to pretreat the wastewater. The electrodialysis performance of wastewater before and after pretreatment was examined. The results show that when the wastewater was pretreated at 60 ℃ for 30 min at the initial activated carbon concentrations of 100 and 200 g/L respectively, the decolorization rate of wastewater was 61% and 75%. In the electrodialysis process ofwastewater pretreated without and with 100 and 200 g/L of activated carbon, the removal rate of lactic acid was sequentially reduced, glutamic acid removal rate was 24%, 35% and 39%, sulfate ions removal rate 77%, 80% and 84%, and ammonium ions removal rate 89%, 86% and 84%, the resistance of membrane stacks increased as well. When sulfate ion removal rate was 85%, energy consumption was 4.88, 3.93 and 3.64 kW.h/kg, respectively.
出处 《过程工程学报》 CAS CSCD 北大核心 2013年第3期500-504,共5页 The Chinese Journal of Process Engineering
基金 国家科技支撑计划基金资助项目(编号:2011BAC11B03)
关键词 废水 活性炭 脱色 电渗析 脱盐 能耗 wastewater activated carbon decolorization electrodialysis desalination energy consumption
  • 相关文献

参考文献20

二级参考文献79

  • 1凌艳艳,朱岩,施青红,朱京平,陈建芳.离子色谱-积分安培检测法测定气溶胶中的氨基酸[J].分析化学,2004,32(9):1267-1267. 被引量:4
  • 2张艳华,田景新,陆际林.电渗析在化工行业中应用展望[J].辽宁化工,1997,26(2):70-72. 被引量:15
  • 3Lui H, Worthen H G. Measurement of Free Amino Acid Levels in Ultrafiltrates of Blood Plasma by High-performance Liquid Chromatography with Automatic Pre-column Derivatization [J]. J. Chromatogr.: Biomed. Appl., 1992, 579(2): 215-224.
  • 4Marianne K, Heiner E. Derivatization of Peptides for Their Determination by Chromatographic Methods [J]. Anal. Chim. Acta, 1997, 352(1/3): 31-59.
  • 5Ianssen P S L, Van Nispen J W, Melgers P A T A, et al. HPLC Analysis of Phenylthiocarbamyl (PTC) Amino Acids [J]. Chromatographia, 1986, 22(7/12): 345-350.
  • 6Petritis K, De Person M, Elfakir C, et al. Validation of an Ion-interaction Chromatography Analysis of Underivatized Amino Acids in Commercial Preparation Using Evaporative Light Scattering Deteceion [J]. Chromatographia, 2004, 60(5/6): 293-298.
  • 7Xu J M, Wang Y P, Xian Y Z, et al. Preparation of Multiwall Carbon Nanotubes Film Modified Electrode and Its Application to Simultaneous Determination of Oxidizable Amino Acids in Ion Chromatography [J]. Talanta, 2003, 60:1123-1130.
  • 8Ding Y S, Yu H, Mou S F. Off-line Elimination of Carbohydrates for Amino Acid Analysis of Samples with High Carbohydrate Content by Ion-exchange Chromatography [J]. J. Chromatogr. A, 2003, 997: 155-160.
  • 9Petritis K, Elfakir C, Dreux M. A Comparative Study of Commercial Liquid Chromatographic Detectors for the Analysis of Underivatized Amino Acids [J]. J. Chromatogr. A, 2002, 961: 9-21.
  • 10Zhang X S, Jiang X P. Low Pressure Ion Chromatography [J]. J. Chromatogr. A, 1994, 671 : 23-28.

共引文献549

同被引文献24

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部