ICL-晶状体间距和虹膜张力对ICL术后并发白内障影响研究 被引量:11

The research on the significance of both the distances from ICL to lens and iris tension in complicated cataract after ICL implant
原文传递
导出
摘要 目的研究ICL(Implantable contact lens,ICL)晶状体的距离以及虹膜张力在ICL并发白内障中的意义。方法临床病例对照研究。对2006年8月至2012年8月在深圳市眼科医院就诊患者,采用眼前段全景OCT观察并发白内障患者ICL在后房的位置变化,并采用Independent-Samples T Test与无并发白内障的患者进行比较。结果瞳孔散大后,ICL并发白内障患者的ICL周边部距晶状体前表面最小间距(D3值)为(77.75±8.70)μm,变化范围69.05~86.45μm;ICL合并正常晶状体患者的D3值为(145.68±28.88)μm,变化范围116.8-174.56μm,二者进行Independent-Samples T Test,P=0.001〈0.05,差异有统计学意义。ICL并发白内障患者D2-D1值(虹膜张力差)为(321±21.31)μm,变化范围299.69-342.31μm;ICL术后透明晶状体患者的D2-D1值为(286.32±60.46)μm,变化范围225.86-346.78μm,P=0.03〈0.05,差异有统计学意义。结论ICL周边部距晶状体前表面的最小间距(D3值)和虹膜张力差(D2-D1值)在并发性白内障的发病机制中具有重要作用。D3值大于116.8μm是相对安全的间距,发生并发性白内障的几率较小;当D3小于86.45μm和D2-D1值大于299.69μm时,并发性白内障的几率增大。 Objective To study the significance of the distances from ICL to lens and iris ten- sion in complicated cataract of ICL. Methods Based on the position changes of ICL in the posteri- or chamber with complicated cataract patients and with no complicated cataract patients with anterior segment and full-field optical coherence tomography, the data of the two group were analysed with the Independent-samples T Test. Results Under mydriasis, the average minimum distance between ICL peripheral part and the front surface of lens (D3 value) in study group was (77,75 ± 8.70)μm, ranged from 69.05 to 86.45μm, and (145.68±28.88)μm, ranged from 116.8 to 174.56μm in control group. The Independent-samples T Test showed the highly significant difference statistically between them (P =0.03〈0.05); The iris tension differential (D2-Dlvalue) was respectively (321±21.31)μm(range 299.69 to 342.315μm) and (286.32±60.46)μm (range 225.86 to 346.78μm) in study group and control group. A statistical comparison between the two groups is significant with regard to iris tension (P =0.03〈0.05) . Conclusions The minimum distance between the peripheral part of ICL and the front surface of lens (D3 value) and the iris tension (D2-D1 value) is of great significance in the etiology of complicated cataract after ICL implant. D3 value of more than l16.8μm is relative- ly safe and not easy to cause lens opacity. But D3 value less than 86.45μm and D2-D1 value more than 299.69μm would increase the chance of contact between the ICL and the lens and then the oc- currence of post-operative cataract.
出处 《中国实用眼科杂志》 CSCD 北大核心 2013年第6期684-687,共4页 Chinese Journal of Practical Ophthalmology
基金 深圳市科技计划项目(200902121)
关键词 ICL 并发性白内障 虹膜张力 眼前节OCT hnplantable contact lens(ICL) Complicated cataract Iris tension Anterior segmentoptical coherence tomography
  • 相关文献

参考文献8

  • 1Gonvers M,Bomet C,Othenin-Girard P.Implantable contactlens for moderate to high myopia:relationship of vaulting tocataract formation [J].J Cataract Refract Surg, 2003, 29:918-924.
  • 2Lackner B, Pieh S, Schmidinger G, et al.Outcome after treat-ment of ametropia with implantable contact lenses [J].Ophthal-mology,2003,110:2153-2161.
  • 3洪佳旭,孙兴怀.眼前节相干光断层扫描技术的临床应用进展[J].中华眼科杂志,2010,46(5):476-480. 被引量:18
  • 4袁芳,季健.OCT在眼前段成像中应用[J].中国实用眼科杂志,2009,27(4):323-326. 被引量:10
  • 5Baikoff G, Lutun Ek, Wei J, et al.Anterior chamber optical co-herence tomography study of human natural accommodation ina 19-year-old albino [J].J Cataract Refract Surg, 2004, 30:696-701.
  • 6Baikoff G, Lutun E, Ferraz C.Static and dynamic analysis of theanterior segment with optical coherence tomography [J].J Cata-ract Refract Surg, 2004,30:1843-1850.
  • 7Baikoff G,Lutun E,Ferraz C,et al.Analysis of the eye’s anteri-or segment with optical coherence tomography.Static and dyam-ic study[J].J Fr Ophtalmol,2005,28:343-352.
  • 8Grieve K,Paques M, Dubois A, et al.Ocular tissue imagingusing Ultrahigh-resolution, full-field optical coherence tomogra-phy[J].Invest Ophthalmol Vis Sci, 2004,45:4126-4131.

二级参考文献4

共引文献20

同被引文献58

引证文献11

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部