摘要
全并联自耦变电器AT(auto transforme)r供电方式在我国高速铁路、客运专线得到了大规模的应用。基于牵引变压器采用次边无中心抽头的单相变压器,在变电所处变压器次边中心不接入钢轨和地。采用广义对称分量法分析短路阻抗特性,绘制AT供电方式下T-R故障的短路阻抗与距离的曲线。证明常用的AT中性点吸上电流比测距原理不能完全适用于该供电方式,并提出了基于AT吸上电流比原理和上下行电流比原理的综合故障测距方案,基于Matlab/Simulink的仿真分析表明,测距原理准确、有效。
The AT (Auto Transformer) power supply mode with parallel connection is applied on high railway and dedicated passenger lines in our country on a large scale. The traction transformer is single phase without neutral termi- nal in secondary side and the mid-point in secondary side is not connected with the rails and earth. Based on the gen- eralized method of symmetrical components, the short-circuit impedance was analyzed. The impedance characteristic curves of T-R fault are plotted. The usual fault location principle based on ratio of AT boosting currents at mid-point is not perfectly adapted to this power supply system. A new fault location comprehensive scheme based on ratio of AT boosting currents and ratio of up-down line currents is put forward. Simulation analysis on Matlab/Simulink indicates that the fault location principle is accurate and effective.
出处
《电力系统及其自动化学报》
CSCD
北大核心
2013年第3期31-34,共4页
Proceedings of the CSU-EPSA
基金
国家自然科学基金项目(50907055)
铁道部科技研究开发计划项目(2011J023-C)
中央高校基本科研业务费专项资金项目(SWJTV12CX034)
关键词
供电牵引网
供电方式
故障测距
中性点吸上电流比
power traction network
power supply mode
fault location
ratio of boosting currents at mid-point