一种新型植物动力学荧光仪

A NEW TYPE OF THE PLANT KINETICS FLUOROMETER
下载PDF
导出
摘要 A new type of home-made computer-controlled non-modulated chlorophyll a fluorometer, the Plant Productivity Fluorometer PFM-101, is introduced including its main features, design and some applications. By using a latest highly integrated PIN-photodiode and FET linear amplifier in the PFM-101 the fluorescence kinetics curves and various fluorescence parameters can be measured and calculated automatically. It has superiority over the commercialized foreign ones in its versatile functions, super-low power consumption, high accuracy, low zero drift, low background noise and high stability etc. The errors produced in the measuring process are reduced to minimum by a unique data processing. Especially, the constant (Fo) and the inflection fluorescence (FI) can be determined with great precision and the inactive PS II reaction center can be calculated automatically. The instrument can be widely used in the field of agriculture, forestry, plant physiology and plant ecology, etc. A new type of home-made computer-controlled non-modulated chlorophyll a fluorometer, the Plant Productivity Fluorometer PFM-101, is introduced including its main features, design and some applications. By using a latest highly integrated PIN-photodiode and FET linear amplifier in the PFM-101 the fluorescence kinetics curves and various fluorescence parameters can be measured and calculated automatically. It has superiority over the commercialized foreign ones in its versatile functions, super-low power consumption, high accuracy, low zero drift, low background noise and high stability etc. The errors produced in the measuring process are reduced to minimum by a unique data processing. Especially, the constant (Fo) and the inflection fluorescence (FI) can be determined with great precision and the inactive PS II reaction center can be calculated automatically. The instrument can be widely used in the field of agriculture, forestry, plant physiology and plant ecology, etc.
出处 《生物物理学报》 CAS CSCD 北大核心 2000年第1期183-186,共4页 Acta Biophysica Sinica
基金 中国科学院资助 国家基金委资助! (编号 :39670068 39800086) 北京市基金委资助!(编号 :6972012)的部分资助
关键词 植物动力学荧光仪 植物产量荧光仪 设计 性能 Chlorophyll Fluorescence kinetics Fluorometer Design
  • 相关文献

参考文献7

二级参考文献19

  • 1卢从明,张其德,匡廷云.水分胁迫对小麦叶绿素a荧光诱导动力学的影响[J].生物物理学报,1993,9(3):453-457. 被引量:72
  • 2裴真明,傅伟,郭连旺,汤章城.MFMS-2叶绿素荧光仪毫秒信号的数字化和计算机采集[J].植物生理学通讯,1994,30(6):446-448. 被引量:2
  • 3Cao J G,Biochim Biophys Acta,1990年,1015卷,180页
  • 4林世青,植物学集刊,1994年,7期,238页
  • 5Cao J,Biochim Biophys Acta,1990年,1015卷,180页
  • 6林世青,Current Research in Photosynthesis Vol 4,1990年
  • 7林世青,植物学集刊,1994年,7卷,238页
  • 8Cao J,Biochim Biophys Acta,1990年,1015卷,180页
  • 9林世青,Advances in photosymthesis ResearchVol.I,1984年
  • 10林世青,Photosynthesis.from Light to Biosphere,Montpellier,Dordrecht,1994年,673页