摘要
针对陕西渭河煤化工集团地下水预脱盐系统进水水质受油污染现状,分析了反渗透膜系统的运行情况,对比了膜污染清洗过程中采用的几种化学药剂的清洗效果,得出了最佳解决方案,并对此类反渗透系统油污染的预防及解决提出了几点建议。
According to the oil pollution in influent of the underground water pre-desalination system of Weihe Coal Chemical Group, this paper analyzed the reverse osmosis system operation and compared the cleaning effects of different chemical drugs used for membrane fouling cleaning. The optimized solution was proposed and several suggestions were also brought forward about the prevention and solution of this kind of reverse osmosis system oil contamination fouling.
出处
《给水排水》
CSCD
北大核心
2013年第7期53-56,共4页
Water & Wastewater Engineering
关键词
反渗透
膜系统
油污染
化学清洗
Reverse osmosis
Membrane system
Oil contamination fouling
Chemical cleaning