摘要 目的了解家用净水器零部件的卫生质量,为家用净水器的卫生监督管理提供依据。方法按照《卫生部涉及饮用水卫生安全产品检验规定》(2001),对2010年送检的家用净水器零部件进行卫生安全性检测。结果家用净水器水处理材料中活性炭滤芯(16.39%,20/122)和离子交换树脂(25.00%,10/40)的不合格率相对较高;输配水设备中端帽(20.83%,5/24)和密封圈垫(33.30%,4/12)不合格率相对较高。超标的项目主要包括TDS,氟化物,三氯甲烷,耗氧量、挥发酚、铅、砷、汞、镍、锌。结论活性炭滤芯、离子交换树脂、端帽和密封圈垫的卫生质量是制约家用净水器卫生质量的主要因素,应对其加强卫生监督管理。 Objective To analyze the main influencing factors of the health security and provide the basis for health supervision and management of household water purifier. Methods According to the relative national regulation, household water purifier parts were detected for health safety in 2010. Results The main failed factors of water treatment components in household water purifier were the carbon filter and ion exchange resin,unqualified rates of 16. 39% and 25.00% , respectively; the failed main factors of water distribution fittings were the end cap and seal pad ,unqualified rates of 20. 83% and 33.30%, respectively. The main unqualified factors included TDS, fluoride, chloroform, oxygen consumption, phenol, lead, arsenic, mercury nickel, and zinc. Conclusion The sanitary quality of carbon filter, ion exchange resin, the fat end cap and seal pad restricts the health security of household water purifiers, so the health supervision and management should be strengthened to the above -mentioned factors.
作者 廖岩 胡俊明
出处 《中国卫生工程学》 CAS 2013年第3期217-218,共2页 Chinese Journal of Public Health Engineering
关键词 家用净水器 零部件 卫生 Household water purifier Parts Health
  • 相关文献

参考文献2

  • 1中华人民共和国环境保护部.中国环境状况公报[R].北京:中国环境科学出版社,2005.
  • 2宫靖,刘虹桥.自来水真相[J].新世界周刊.2012,18:1-3.

同被引文献33

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部