摘要 应用放射源激发闪烁体发光,测量发光时间特性的单光子计数法,以及按单光子计数原理建立的测量装置,对国产ST401型普通塑料闪烁体的闪烁衰减时间进行了测量,结果为(2.60±0.18)ns。该装置的时间分辨率小于1.8 ns,幅度动态范围大于104,测量精度好于0.1 ns,并可以测量多组份发光时间的闪烁体的时间特性。 The Decay Time of ST401 Type Plastic Scintillator has been measured by Single Photon method. The result is (2.60 +0.18)ns. This device has an intrinsic time resolution less than 1.8 ns, and has a dynamic range of more than 104, and the time measurement accuracy less than 0.1 ns. This devide can be used to meas- ure the time characteristics of multi - source scintillators.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2013年第4期462-466,共5页 Nuclear Electronics & Detection Technology
关键词 闪烁体 塑料闪烁体 闪烁衰减时间 单光子法 scintillator plastic scintillator decay time of scintillation method of single photon
  • 相关文献

参考文献3

  • 1汲长松.核辐射探测器及其实验技术手册[M].2版,北京:原子能出版社,2010.
  • 2贺宣庆.单光子计数时间测量装置[R].中核(北京)核仪器厂技术报告,1986.
  • 3汲长松,罗凤群,贺宣庆,等.GB/T13181-2002,闪烁体性能测试方法[S].北京:中国标准出版社,2002.

同被引文献13

  • 1Lindl J D, Amendt P, Berger R L, et al. The physics basis for ignition using indirect-drive targets on the national ignition facility[J]. Physics of Plasmas, 2004, 11(2): 339-491.
  • 2Bollinger L M, Thomas G E. Measurement of the time dependence of scintillation intensity by a delayed- coincidence method[J]. Review of Scientific Instruments, 1961, 32(9): 1044-1050.
  • 3Moszyfiski M, Bengtson M B. Status of timing with plastic scintillation detectors[J]. Nuclear Instruments and Methods, 1979, 158:1-31.
  • 4Zhong W L, Li Z H, Yang C G, et al. Measurement of decay time of liquid scintillator[J]. Nuclear Instruments and Methods in Physics Research, 2008, A587(2): 300-303.
  • 5Hatarik R, Bernstein L A, Caggiano J A, et al. Characterizing time decay of bibenzyl scintillator using time correlated single photon countinga[J]. Review of Scientific Instruments, 2012, 83(10): 10D911.
  • 6EJ-232 plastic scintillator[EB/OL], http:llwww. southernscientific.co.uk, 2015.
  • 7张松寿,李润新,王清芳.一种先进的电流-频率变换器[J].核电子学与探测技术,1999,19(5):370-372. 被引量:2
  • 8彭晓世,王峰,徐涛,刘永刚,刘慎业,梅雨,陈铭.快响应塑料闪烁体EJ-232的时间特性研究[J].光学学报,2011,31(12):171-175. 被引量:6
  • 9王宝林,刘凤玲.塑料闪烁体在中子辐照下发光特性的研究[J].核技术,1991,14(9):535-540. 被引量:1
  • 10林久令,董志山,张秀峰,骆永石,王遵立,孙铁铮,林海,刘行仁.荧光衰减曲线的一种多指数拟合方法[J].发光学报,2002,23(1):93-96. 被引量:8

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部