期刊文献+

X射线检测仿真软件成像的黑度修正 被引量:3

Method of Film Density Correction in Computer Simulated X-Ray Radiograph
下载PDF
导出
摘要 X射线仿真软件通过读取物体三维模型,基于射线衰减及成像理论,计算得到理想探测器成像的射线图像。由于射线机、胶片、环境等方面与实际检测相比存在着一定的差异,导致射线仿真软件成像与实际检测图像的黑度上不一致。以X射线仿真软件(X-RAY Simulation)为例,通过对比它与真实X射线机对钛合金零件曝光图像的黑度差异,利用软件自带的修正功能制作出修正系数曲线对仿真图像的黑度进行修正。试验证明最大黑度差由1左右降至0.3。 Radiography Simulation Software produces simulated radiograph by loading three-dimensional data of the part to be inspected and by calculating based on X-ray attenuation and imaging theory. However, there are some differences between the simulated images and real images due to variation of ray-machine, film, environment and other factors. In this paper, the differences of density between simulated and real images were investigated by using software of XRSIM. Correction factor curve was made to correct the densityof simulated X-ray radiograph. Experimental results show that the biggest differencesof density are decreased from 1.0 to O. 3.
出处 《无损检测》 2013年第6期53-56,共4页 Nondestructive Testing
关键词 射线仿真软件 黑度 修正系数曲线 Simulation Software of Radiography density Correction coefficient curve
  • 相关文献

参考文献4

  • 1孙朝明,王增勇.射线检测中的仿真技术发展[J].无损检测,2006,28(9):475-478. 被引量:5
  • 2郑世才.射线检测[M].北京:机械工业出版社,2004..
  • 3王倩妮,郭广平.射线检测计算机仿真技术在铸件检测中的应用[C]//全国第九届无损检测学术年会论文集.[s.1].[s.n],2010:817-821.
  • 4李晓丽.X射线仿真软件及其应用[C]//全国射线数字成像与CT新技术论文集.[S.1]:[s.n],2009.

二级参考文献9

  • 1Nicolas Freud, Philippe Duvaucheue, Daniel Babot, et al. Simulation of X-ray NDT imaging techniques[A].15th World Conference on Non-Destructive Testing[C]. Rome. 2000.
  • 2Mathy F, Guillemaud R, Picone M, et al. Experimental validation of a couple photon Monte Carlo and CAD software[J]. Nuclear Instruments and Methods in Physics Research, 2003,504A: 317-320.
  • 3Bonin A, Chalmond B, Lavayssiere B, et al. Monte-Carlo simulation of industrial radiography images and experimental designs [J]. NDT&E International,2002,35: 503-510.
  • 4Bonin A, Lavayssiere B. New advances in the development of MODERATO[A]. 15th World Conference on Non-Destructive Testing[C]. Rome: 2000.
  • 5Tillack GR, Nockemann C, Bellon C, et al. X-ray modeling for industrial applications [J]. NDT&E International, 2000,33: 481-488.
  • 6Inanc F, Gray J. New developments in the computer simulation of X-ray nondestructive evaluation process[J]. Review of Progress in Quantitative Nondestructive Evaluation, 1991,10A: 355-361.
  • 7Tillack GR, Bellon C, Nockemann C, et al. Computer simulation of radiographic process-a study of complex component and defect geometry[J]. Review of Progress in Quantitative Nondestructive Evaluation, 1995,14: 665-672.
  • 8Carsten Bellon, Tillack GR, Nockemann C, et al.Computer simulation of X-ray NDE process coupled with CAD interface[J]. Review of Progress in Quantitative Nondestructive Evaluation, 1997, 16: 325-330.
  • 9Koenig A, Gliere A, Rizo P, et al. Object pose estimation using a set of local radiographs of a part and its CAD model[J]. Review of Progress in Quantitative Nondestructive Evaluation, 1997,16:829-836.