期刊文献+

硅振荡器的抗高过载实验设计与分析 被引量:2

The Design and Analysis of Experiment for Silicon Oscillator in High- Acceleration Environment
下载PDF
导出
摘要 硅振荡器是一种在高过载条件下有可能代替石英晶体振荡器为应用系统提供稳定时钟的振荡器。对硅振荡器开展高过载实验研究,具有重要的应用价值。论文以LTC6909I型硅振荡器为实验对象,对高过载环境下可能产生的频率漂移及是否损坏这两个主要方面进行了实验研究。实验证明了硅振荡器能经受高过载环境的考验,可以代替石英晶体振荡器为应用系统提供稳定时钟。 Silicon oscillator is a kind of oscillator that may replace quartz crystal oscillator for the application system to provide a stable clock in high acceleration conditions. The research for silicon oscillator in high acceleration environment has important application value. Based on LTC6909I type silicon oscillator, the paper elaborates two main aspects of the experimental study: possible frequency drift and the damage of the silicon oscillator in high acceleration conditions. Experiments show that the silicon oscillators can withstand high acceleration test, and can replace the quartz crystal oscillator for the application system to provide a stable clock.
出处 《电子器件》 CAS 北大核心 2013年第3期332-335,共4页 Chinese Journal of Electron Devices
关键词 硅振荡器 高过载 马歇特锤击实验 炮击实验 silicon oscillator high acceleration Machete hammer penetration test
  • 相关文献

参考文献8

二级参考文献26

  • 1张菁华,石庚辰,隋丽.引信用微压阻式加速度传感器系统设计[J].装备指挥技术学院学报,2005,16(3):82-86. 被引量:9
  • 2石云波,祁晓瑾,刘俊.引信用MEMS加速度传感器敏感元件的设计[J].半导体技术,2006,31(7):537-541. 被引量:9
  • 3王正平.冲击载荷下减振系统的优化设计[D].北京:北京理工大学机电工程学院,2002.
  • 4《振动与冲击手册》编辑委员会.振动与冲击手册[M].北京:国防工业出版社,1992.
  • 5徐鹏.裸硅片及芯片的抗高g值冲击性能[C]//中国力学学会学术大会.北京:中国力学学会,2007.
  • 6Darrin J. Young, Bernhard E. Boser, A Micromachine-Based RF Low-Noise Voltage-Controlled-Oscillator[C]/// Technical Digest of Custom Integrated Circuits Conference, Santa Clara,CA , 1997:431-434.
  • 7Darrin J. Young, Vincent Mabla, Jia-Jiunn Ou, et al. A Low-Noise RF Voltage-Controlled Oscillator Using On-Chip High-Q Three-Dimensional Coil Inductors and Micromachined Variable Capacitor, Technical Digest[C] ff IEEE Solid-State Sensor and Actuator Workshop, Hilton Head Island, South Carolina, 1998: 128-131.
  • 8Darrin J. Young, Joo L. Tham, and Bernhard E. Boser, A Micromachine-Based Low Phase-Noise GHz Voltage-Controlled Oscillator for Wireless Communications[C]/// Technical Digest of the 10th International Conference on Solid-State Sensors and Acuators, Sendal, Japan, 1999: 1386-1389.
  • 9Aleksander Dec, Ken Suyama, Micromachined Electro-Mechanically Tunable Capacitors and Their Applications to RF IC's[J]. IEEE Transactions on Microwave Theory and Techniques, 1998,46(12): 2587-2596.
  • 10Aleksander Dec, Ken Suyama, 1.9GHz Mieromaehined-Based Low-Phase-Noise CMOS VCO[J]. IEEE ISSCC Dig. Tech.Papers, Feb. 1999,80-81.

共引文献25

同被引文献21

  • 1李乐,祖静,徐鹏.EXO3晶振与KSS晶振在高过载下的失效特性分析[J].中国测试技术,2007,33(3):88-90. 被引量:7
  • 2GJB2973A-2008火炮内弹道试验方法[S].北京:总装备部军标出版发行部.2008.
  • 3王卿.放入式电子测压器的智能化设计及校准技术研究[D].中北大学,2011.
  • 4FOSTER J T,FREW D J,FORRESTAL M J,et al.Shock testing accelerometers with a Hopkinson pressure bar[J].Inter J Impact Engin,2012,46:56-61.
  • 5FORRESTAL M J,TOGAMI T C,BAKER W E,et al.Performance evaluation of accelerometers used for penetration experiments[J].Exp Mechan,2003,43(1):90-96.
  • 6TOGAMI T C.A split Hopkinson bar technique to evaluate the performance of accelerometers[J].J Appl Mechan,1996,63(2):353-356.
  • 7SU H,XU J,REN W.Mechanical properties of ceramic fiber-reinforced concrete under quasi-static and dynamic compression[J].Mater Des,2014,57:426-434.
  • 8TREXLER M M,LENNON A M,WICKWIRE A C,et al.Verification and implementation of a modified split Hopkinson pressure bar technique for characterizing biological tissue and soft biosimulant materials under dynamic shear loading[J].J Mech Behav Biomedical Mater,2011,4(8):1920-1928.
  • 9BATEMAN V I,LEISHER W B,BROWN F A,et al.Calibration of a hopkinson bar with a transfer standard[J].Shock Vibration,1993,1(2):145-152.
  • 10刘卫,沈瑞琪,叶迎华,等.火工品高过载试验方法的比较[C]//第九届全国爆炸力学学术会议.西宁:中国力学学会,2012.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部