期刊文献+

功率、时间和间距对离体猪心双极射频消融的影响

Effect of power, time and space on isolated pig heart bipolar radiofrequency ablation
原文传递
导出
摘要 目的研究临床条件下多参数双极射频消融在离体猪心上形成的消融灶的形态大小,评价双极射频消融的有效性和安全性。方法在预设功率(30w和40w)和灌注条件(1250mL/h)下用4mm的大头双极消融电极对新鲜离体猪心进行消融,电极间距离从12—17mm,时间从20~90S,测定交汇消融灶的长度、深度、连接率和爆破率。结果时间增加时,长度、深度、连接率、爆破率都增加;间距增加时,长度增加,深度、连接率、爆破率下降;功率增加时,长度、连接率、爆破率增加,深度减小。12mm、20s,30W,有盐水灌注(1250ml/h)时双击消融有效性和安全性最好,长度均值为19.89mm,深度均值为3.94mm,连接率100%,爆破率6%。结论双极消融可以在电极间距离12ITIE、20s、30W、有灌流(1250ml/h)时形成稳定的交汇消融灶。 Objective To investigate the effectiveness and safety of clinical bipolar radiofrequency ablation in vitro pigs hearts on different conditions. Methods The effects of bipolar radiofrequency ablation in the power of 30 W and 40 W,with a 4 mm bipolar electrode, electrode distance from 12 mm to 17 ram,time from 20 s to 90 s, cold saline perfusion( 1250 ml/h)on isolated fresh pigs hearts were evaluated.The lesion size including lengthand depth, connection rate and blasting rate were measured. Results As time increases, the lesion length was increased, depth, connection rate, blasting rate increased;as distance increases, the lesion length was increased, connection rate ,blasting rate were reduced; as power increases, the lesion length, con- nection rate, blasting rate were increased while the depth was reduced.The effectiveness and safety was the best when using 12 ram,20 s,30 W, 1250 ml/h,the mean lesion length was 19. 89 ram, the average depth was 3.94 ram,connection rate was 100%, blasting rate was 6%.Conclusion Bipolar radiofrequency ablation in power of 30 W, bipolar electrode with 12 mm,20 s, 1250 ml/h waseffectiveness and safety.
出处 《中华心律失常学杂志》 2013年第3期210-213,共4页 Chinese Journal of Cardiac Arrhythmias
基金 2011上海市科学技术委员会实验动物专项资助(11140900800) 2012上海市科学技术委员会实验动物专项资助(12140902900)
关键词 双极消融 离体猪心 功率 Bipolar ablation Isolated pigs hearts Power
  • 相关文献

参考文献8

  • 1Haissaguerre M, Shah DC, Jais P, et al.Electrophysiological break- throughs from the left atrium to the pulmonary veins. Circulation, 2000, 102:2463-2465.
  • 2Pappone C, Rosanio S, Oreto G, et al.Circumferemial radiofre- quency ablation of pulmonary vein ostia:A new anatomic approach for curing atrial fibrillation. Circulation, 2000, 102 : 2619-2628.
  • 3Demazumder D, Mirotznik MS, Schwartzman D.Comparison of irri- gated electrode designs for radiofrequency ablation of myocardium.J Interv Card Electrophysiol ,2001,5:391-400.
  • 4Demazumder D, Mirotznik MS, Schwartzman D.Biophysics of ra- diofrequency ablation using an irrigated electrode. J Interv Card Electrophysiol, 2001,5 : 377-389.
  • 5Basu S, Nagendran M, Maruthappu M.How effective is bipolar ra- diofrequency ablation for atrial fibrillation during concomitant car- diac surgery.'? Interact CardioVasc Thorac Surg, 2012, 15: 741- 748.
  • 6Onorati F, Rubino AS, Mariscalco G, et al.Results of atrial fibril- lation ablation during mitral surgery in patients with poor electro- anatomical substrate.J Heart Valve Dis, 2009 , 18:607-616.
  • 7赖颢,王春生,丁文军,洪涛,陈昊,过常发.双极射频消融及迷宫术治疗风湿性心脏病合并长期持续性心房颤动[J].中华心律失常学杂志,2009,13(3):206-208. 被引量:1
  • 8Anfinsen OG, Kongsgaard E, Foerster A, et al. Bipolar radiofre- quency catheter ablation creates confluent lesions at larger inter- electrode spacing than does unipolar ablation from two electrodes in the porcine heart.Eur Heart J, 1998, 19:1075-1084.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部