摘要 The conventional double-probe technique was improved with a combination of selfpowering and radio-frequency(RF) choking.RF perturbations in dual-frequency capacitively coupled discharge were effectively eliminated,as judged by the disappearance of self-bias on the probes.The improved technique was tested by spatially resolved measurements of the electron temperature and ion density in both the axial and radial directions of a dual-frequency capacitive plasma.The measured data in the axial direction were compared with simulation results,and they were excellently consistent with each other.The measured radial distributions of the ion density and electron temperature were influenced significantly by the lower frequency(LF) power.It was shown that superposition of the lower frequency to the higher frequency(HF) power shifted the maximum ion density from the radial center to the edge region,while the trend for the electron temperature profile was the opposite.The changing feature of the ion density distribution is qualitatively consistent with that of the optical emission intensity reported. The conventional double-probe technique was improved with a combination of selfpowering and radio-frequency(RF) choking.RF perturbations in dual-frequency capacitively coupled discharge were effectively eliminated,as judged by the disappearance of self-bias on the probes.The improved technique was tested by spatially resolved measurements of the electron temperature and ion density in both the axial and radial directions of a dual-frequency capacitive plasma.The measured data in the axial direction were compared with simulation results,and they were excellently consistent with each other.The measured radial distributions of the ion density and electron temperature were influenced significantly by the lower frequency(LF) power.It was shown that superposition of the lower frequency to the higher frequency(HF) power shifted the maximum ion density from the radial center to the edge region,while the trend for the electron temperature profile was the opposite.The changing feature of the ion density distribution is qualitatively consistent with that of the optical emission intensity reported.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第6期511-515,共5页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China(No.10635010) the Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20090041110026)
关键词 dual-frequency capacitive plasma double probe plasma diagnosis dual-frequency capacitive plasma double probe plasma diagnosis
  • 相关文献

参考文献20

  • 1Boyle P C, Ellingboe A R and Turner M M. 2004, J. Phys. D: Appl. Phys., 37: 697.
  • 2Kojima A, Hayashi H, Sakai I, et al. 2005, Jpn. J. Appl. Phys. Part 1, 44: 6241.
  • 3Ohtsu Y, Hino Y, Misawa T, et al. 2007, Surf. Coat. Technol., 201: 6627.
  • 4Perret A, Chabert P, Booth J P, et al. 2003, Appl. Phys. Lett., 83: 243.
  • 5Volynets V N, Ushakov A G, Sung D, et al. 2008, J. Vac. Sci. Technol. A, 26: 406.
  • 6Bera K, Rauf S, Ramaswamy K, et al. 2009, J. Vac. Sci. Technol. A, 27: 706.
  • 7Kitajima T, Takeo Y and Makabe T. 1999, J. Vac. Sci. Technol. A, 17: 2510.
  • 8Koshiishi A, Araki Y, Himori S, et al. 2001, Jpn. J. Appl. Phys. Part 1, 40: 6613.
  • 9Wickramanayaka S and Nakagawa Y. 1998, Jpn. J. Appl. Phys. Part 1, 37: 6193.
  • 10Lisovskiy V A, Yegorenkov V D. 2006, Vacuum, 80: 458.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部