期刊文献+

过冷态超流氦恒温器的热力学分析 被引量:1

Thermodynamic analysis of subcooled superfluid helium cryostat
下载PDF
导出
摘要 对过冷态超流氦恒温器的热力学过程进行分析,考察了不同的设计温度和J-T换热器热效率下恒温器的制冷性能,得到了理论制冷量的变化曲线。结果表明,理论制冷量与设计温度和J-T换热器的热效率密切相关。计算发现,160 L液氦在2 W制冷量下从4.2 K降至1.8 K大约需要24 h。 Thermodynamic analysis of subcooled superfluid helium cryostat was carried out.The influence of different design temperature and different efficiency of J-T heat exchanger on theoretical cooling capacity was analyzed,and theoretical cooling capacity variation curves were also presented.The results show that theoretical cooling capacity is greatly related to design temperature and efficiency of J-T heat exchanger.It will take about 24 h to cool 160 L liquid helium from 4.2 K down to 1.8 K with 2 W cooling capacity.
出处 《低温工程》 CAS CSCD 北大核心 2013年第3期15-17,共3页 Cryogenics
基金 国家磁约束核聚变能研究专项基金(2011GB112004)
关键词 超流氦 低温恒温器 热力学分析 superfluid helium cryostat thermodynamic analysis
  • 相关文献

参考文献4

  • 1张鹏,黄永华,陈国邦.氦4和氦-3及其应用[M].北京:国防工业出版社,2006.
  • 2Augueres J L, Aymar R, Bon Mardion G, et al. 700m diameter eryo- stats operating at 1.8K and atmospheric pressure[ J]. Cryogenics, 1980 (9) :529-532.
  • 3陈煜,郑青榕,汪荣顺,林文胜,鲁雪生,顾安忠.几种获取1.8K超流氦方案的对比分析[J].上海交通大学学报,2005,39(2):234-237. 被引量:7
  • 4沈维道,童钧耕.工程热力学(第四版)[M].北京:高等教育出版社,2007.

二级参考文献4

  • 1Blau B, Harrison S M, Hofer H, et al. The superconducting magner of AMS-02 [J]. IEEE Transactions on Applied Superconductivity, 2002, 12(1):349-352.
  • 2Alpat B, The alpha magnetic spectrometer (AMS) experiment on the international space station [J]. Nuclear Instruments and Methods in Physics Research A, 2001, 461(1-3): 227-274.
  • 3Battiston B. The alpha magnetic spectrometer (AMS) [J]. Nuclear Instruments and Methods in Physics Research A, 1998, 409(1-3):458-463.
  • 4AMS Collaboration. Search for anti-helium in cosmic rays [J]. Physics Letters B, 1999, 461(4):387-396.

共引文献14

同被引文献8

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部