期刊文献+

柔性坐标测量机结构参数标定的采样覆盖率研究 被引量:1

Research on Sampling Coverage of Parameter Calibration for PCMM
下载PDF
导出
摘要 采用非线性最小二乘法作为柔性坐标测量机标定的优良算法,提出采样覆盖率来评定采样是否充分。转角范围和采样角度是各个关节采样覆盖率的必要求解因子,首先通过模拟实验计算各个关节转角变量对测量精度权的大小,并找出权重最大的关节1和关节2,然后对其进行实验对比,结果证明,良好的采样覆盖率会使采样更充分,测量结果更精确。 The nonlinear least squares method is used as the superior algorithm in PCMM calibration process. The concept of sampling coverage is proposed in the paper to assess the adequacy of sampling data. The angular range and the sampling angle are the necessary factors to obtain the sampling coverage of each joint. The value of the affecting factor of each joint angle respected to the final measurement accuracy is calculated by simulation experiments firstly. Joint 1 and joint 2 with the biggest weights are found out and compared with experiments, which show that better sampling coverage leads to fuller sampling with more accurate measuring results
作者 刘菲 于连栋
出处 《电子科技》 2013年第7期4-6,共3页 Electronic Science and Technology
基金 国家自然科学基金资助项目(51075117)
关键词 标定 采样覆盖率 转角变量 权重 calibration sampling coverage angle variable weight
  • 相关文献

参考文献3

二级参考文献27

  • 1王从军,魏霖,李中伟.仿人关节式坐标测量机的数学建模及标定方法[J].华中科技大学学报(自然科学版),2007,35(11):1-4. 被引量:6
  • 2刘万里,曲兴华,闫勇刚.便携式三坐标测量臂校准和误差补偿[J].仪器仪表学报,2007,28(S1):81-84. 被引量:15
  • 3汪平平,费业泰,林慎旺.柔性三坐标测量臂的标定技术研究[J].西安交通大学学报,2006,40(3):284-288. 被引量:31
  • 4叶声华,王一,任永杰,李定坤.基于激光跟踪仪的机器人运动学参数标定方法[J].天津大学学报,2007,40(2):202-205. 被引量:66
  • 5FURUTANI R, SHIMOJIMA K, TAKAMASU K. Parameter calibration for non-cartesian CMM [J]. VDIBerichte, 2004,1860:317-326.
  • 6DENAVIT J, HARTENBERG R. A kinematic notation for lower pair mechanism based on matrices [J]. ASME Journal of Applied Mechnics, 1955,22(6) ..215-221.
  • 7BUREERAT S, LIMTRAGOOL J. Structural topology optimisation using simulated annealing with multiresolution design variables[J].Finite Elements in Analysis and Design, 2008, 44(12-13) :738-747.
  • 8SANTOLARIA J, ANGUILAR J J, YAGUE J A, et al.. Kinematic parameter estimation technique for calibration and repeatability improvement of articulated arm coordinate measuring machines[J]. Precision Engineering, 2008,32(4) : 251-268.
  • 9KOVAC I, FRANK A. Testing and calibration of coordinate measuring arms [J]. Precision Engineering, 2001,25(2) :90-99.
  • 10KOVAC I, KLEIN A. Apparatus and a procedure to calibrate coordinate measuring arms [J]. Journal of Mechanical Engineering, 2002,48( 1 ) : 17-32.