摘要 移相全桥电路零电压开关(ZVS)的实现与死区时间、负载大小、谐振电感、谐振电容的选择等均有关系,这里主要分析了死区时间对移相全桥电路开关过程的影响,并通过试验验证了理论分析的正确性。 The dead-time, the load degree ,the resonant inductance and capacitance all above would affect the phase-shifted full-bridge PWM circuit to implement zero voltage switch(ZVS).The influence of the dead-time are discuss- ed, and the experimental results verify the correctness of theoretical analysis.
出处 《电力电子技术》 CSCD 北大核心 2013年第7期20-21,共2页 Power Electronics
关键词 零电压开关 移相全桥 死区时间 zero voltage switch phase-shifted full-bridge dead-time