摘要
以某大型浮法玻璃熔窑支撑L形吊墙大横梁的立柱为例,介绍了偏心受压立柱的设计计算方法。
A design calculation of eccentric compression column was described by taking a column which supports cross beam of L-shape suspended wall in a large scale float glass furnace as an example.
出处
《玻璃》
2013年第6期3-5,共3页
Glass
关键词
玻璃
熔窑
L吊墙
立柱
glass, fumace, suspended wall , upright post