加氢裂化装置紧急停车联锁逻辑设计 被引量:9

Design of the Interlock Logic of ESD in Hydrocracking Unit
下载PDF
导出
摘要 加氢裂化装置是炼油装置中爆炸和火灾危险性最高的甲类装置,因此,该装置仅有过程控制系统是不够的。为了保障生产设备和操作人员的安全,设计了一套紧急停车联锁逻辑保护系统。根据加氢裂化装置的工艺流程和安全联锁相关设置原则,采用该系统对紧急泄压系统和装置中的主要设备(如新氢压缩机、循环氢压缩机、反应加热炉等)进行联锁逻辑设计。该设计具有一定的工程实践意义。 Hydrocracking unit is one of the Category A devices with highest risk of explosion and fire in oil refining plant. In such device, only equipped with process control system is not enough. In order to protect the safety of production equipment and operating personnel, a whole set of emergency shutdown and interlock protection system is designed. In accordance with the technological process of hydrocracking unit and the setting principles of safety interlock, in the system, the interlock logic is designed for emergency pressure relief system and major equipment in the unit, including fresh hydrogen compressor, circulating hydrogen compressor, and reaction furnace, etc., this design features certain practical and engineering significance.
出处 《自动化仪表》 CAS 北大核心 2013年第7期25-27,31,共4页 Process Automation Instrumentation
基金 南昌市重点基金资助项目(编号:Z03316)
关键词 加氢裂化装置 紧急停车系统 安全联锁系统 DCS 保护系统 新氢压缩机 Hydrocracking unit Emergency shutdown system(ESD) Safety integrated system ( SIS ) Distribution control system( DCS) Protection system Fresh hydrogen compressor
  • 相关文献

参考文献8

二级参考文献7

  • 1国际电工委员会IEC TC65 WG10-1993,电气/电子/可编程的安全系统概况[S].
  • 2SHB-Z06-1999,石油化工紧急停车及安全联锁系统设计导则[S].
  • 3美国仪表协会ISA SP84-1992,安全领域的可编程电子系统[S].
  • 4美国化学工程协会(AICHE(CCPS))-1993,化学过程的安全自动化导则[S].
  • 5英国健康与安全执行委员会(HSE PES)-1987,可编程电子系统在安全领域的应用[S].
  • 6陈尧焕,李鹏.中国石化加氢裂化装置运行分析[J].炼油技术与工程,2007,37(10):1-4. 被引量:14
  • 7廖士纲,韩崇仁.面向21世纪的加氢裂化技术[J].炼油设计,1999,29(5):1-7. 被引量:6

共引文献36