冷凝水加热器设计不合理影响了锅炉的稳定运行。对冷凝水加热器水冲击的原因进行了分析,并阐述了相应的改造措施,提高了设备的稳定性和换热效率。
Unreasonable design of condensate water heater affects stable operation of the boiler. The reason of water impact to condensate water heater is analyzed. The improvement measures are expanded. It improves stability and heat exchange efficiency of the heater.
出处
《冶金动力》
2013年第7期47-48,51,共3页
Metallurgical Power
关键词
冷凝水加热器
水冲击
优化改造
换热效率
condensate water heater
water impact
optimization reconstruction
heat exchange efficiency