期刊文献+

火电厂ECS电气监控系统纳入DCS监控的应用分析 被引量:5

Application and analysis of electrical control system accessed into DCS monitoring
下载PDF
导出
摘要 针对火电厂电气监控系统(ECS)实践应用中,存在与DCS监控通信受限、电气维护和管理功能不健全等问题,认为将ECS系统纳入DCS监控是目前电厂实现智能一体化监控的有效途径。通过全通信方式将ECS系统接入DCS监控中,利用集散控制结构,节点间的通信采用相互独立设置原则,通信结构成熟简单,完善ECS系统电气运行监控能力,提高电厂调控运行信息自动化水平,并节省大量工程投资,实现单元机组智能一体化协同控制,必将成为ECS控制系统发展主流。 Abstract: In order to solve the problems of limited communication with DCS system, dysfunctional electrical maintenance and management in the practical application of thermal power plant electrical control system (ECS) ,think that now the effective way for thermal power plant to realize the intelligent integrated monitoring is connecting ECS into DCS. ECS system access into the DCS system through the full communication with the distributed control structure and each node point communicates independently, which can improve the ECS operation monitoring capability. The automation control level of the thermal power plant operation information can be raised, lots of engineering investment can also be saved, and the units intelligent integrated cooperation control function can be realized. It will become the development mainstream of the ECS control system.
作者 佘丹宁
出处 《电气传动自动化》 2013年第3期39-43,共5页 Electric Drive Automation
关键词 火电厂 电气监控系统(ECS) 分散控制系统(DCS) 一体化监控 全通信 thermel power plant electrical control system(ECS) distributed control system(DCS) Integrated monitoring full communication