摘要
通过对脱硫增压风机变频改造,使增压风机由长期恒速运行转变为自动变频变速运行,改善了电机启动特性,提高了厂用电系统的稳定性和脱硫系统故障后的快速恢复,并取得了显著的节能效果。
Based on the frequency transformation of desul- phurization booster fan, the long-term constant speed operation of the booster fan is changed into the automatic variable speed operation, which improves starting characteristic of motor, im- proves the rapid recovery of the station service system stability & desulfurization system after fault and has achieved remarkable energy-saving effect.
出处
《电力学报》
2013年第3期238-240,共3页
Journal of Electric Power
关键词
300
MW机组
脱硫
增压风机
变频改造
300 MW generating unit
desulfuration
bo-oster fan
frequency conversion transformation