期刊文献+

Determination of phenolic whitening agents in cosmetics by micellar electrokinetic capillary chromatography with amperometric detection 被引量:6

Determination of phenolic whitening agents in cosmetics by micellar electrokinetic capillary chromatography with amperometric detection
原文传递
导出
摘要 A sensitive method for simultaneous determination of six phenolic whitening agents, including arbutin, phenol, resorcinol, hydroquinone, kojic acid, and salicylic acid in cosmetics has been developed using micellar electrokinetic capillary chromatography with amperometric detection (MECC-AD). Effects of several factors, such as the pH value and concentration of running buffer, potential applied to the working electrode, separation voltage, and injection time were investigated to obtain optimum conditions for separation and detection. With a 75 cm long fused-silica capillary tube, well-defined separation of six phenolic compounds was achieved in 10 mmol/L SDS/40 mmol/L H3BO3-Na2B407 running buffer (pH 9.0). Good linear relationship was obtained for each analyte over three orders of magnitude with correlation coefficients (r2) between 0.9985 and 0.9994, and the detection limit (S/N = 3) ranged from 0.04 p^g/mL to 0.45 p^g/mL. The proposed method has been successfully applied for the determination of phenolic whitening agents in real cosmetic samples with satisfactory results, providing an alternative monitoring method for cosmetics safety regulation. A sensitive method for simultaneous determination of six phenolic whitening agents, including arbutin, phenol, resorcinol, hydroquinone, kojic acid, and salicylic acid in cosmetics has been developed using micellar electrokinetic capillary chromatography with amperometric detection (MECC-AD). Effects of several factors, such as the pH value and concentration of running buffer, potential applied to the working electrode, separation voltage, and injection time were investigated to obtain optimum conditions for separation and detection. With a 75 cm long fused-silica capillary tube, well-defined separation of six phenolic compounds was achieved in 10 mmol/L SDS/40 mmol/L H3BO3-Na2B407 running buffer (pH 9.0). Good linear relationship was obtained for each analyte over three orders of magnitude with correlation coefficients (r2) between 0.9985 and 0.9994, and the detection limit (S/N = 3) ranged from 0.04 p^g/mL to 0.45 p^g/mL. The proposed method has been successfully applied for the determination of phenolic whitening agents in real cosmetic samples with satisfactory results, providing an alternative monitoring method for cosmetics safety regulation.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2013年第7期636-638,共3页 中国化学快报(英文版)
基金 supported by the Natural Science Foundation of China(No.21205042) the Special Funds for the Development of Major Scientific Instruments and Equipment(No. 2011YQ15007205)
关键词 Micellar electrokinetic capillary chromatography Amperometric detection Phenolic whitening agents Cosmetics Micellar electrokinetic capillary chromatography Amperometric detection Phenolic whitening agents Cosmetics
  • 相关文献

参考文献1

二级参考文献1

共引文献2

同被引文献59

引证文献6

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部