摘要 华能汕头发电厂 1号蒸汽轮机组在大修后启动及运行过程中发生了大轴振动大的故障。通过剖析机组的结构 ,分析引起振动的各种影响因素 ,得出 :低压缸排汽温度高是引起启动过程振动大的直接原因 ,冷凝器循环水入口压力大是引起运行过程振动大的原因。提出的故障处理方法是 :以稍开低压旁路及给低压旁路喷水 ,并启动第 2台主抽汽器来解决启动过程出现的振动故障 ;采取调节冷凝器海水回水阀 ,使入口两侧压力小于或等于 0 10MPa来解决运行过程的振动故障。 The overhauled Steam Turbo unit 1 of Huaneng Shantou Power Plant incurred superstandard vibration during start up and operational periods. With the analysis of the unit structure and various influencing factors which may cause the vibration, it draws a conclusion that the high exhaust steam temperature of LP cylinder is the immediate cause of the vibration in start up period, while the great circulating water inlet pressure of the condenser is the reason for the vibration during operation. The author suggests that the former vibration be eliminated by slightly opening the LP by pass, spraying on it and starting the second main vapor extractor; the latter vibration be removed by adjusting the seawater return valve of the condenser to make pressure on both sides of the inlet equal to or less than 0 10 MPa.
作者 孙伟鹏
出处 《广东电力》 2000年第4期56-57,60,共3页 Guangdong Electric Power
关键词 汽轮发电机组 振动 故障分析 故障处理 发电厂 LP cylinder condenser exhaust steam temperature pressure vibration steam turboset
  • 相关文献

同被引文献11

  • 1聂清德,谭蔚,朱雨峰,段振亚,周连刚.冷凝器中弓形折流板结构与两相流诱发的振动[J].石油化工设备,2007,36(2):1-5. 被引量:1
  • 2东南大学振动研究所 陆颂元.汽论发电机组振动[M].中国电力出版社,2000,2..
  • 3陆颂元 邓陈兵 等.清镇发电厂七号汽轮机组改造后轴系振动动测试及高速平衡[M].,2000,9..
  • 4张卓澄.大型电站凝汽器[M]北京:机械工业出版社,1993.
  • 5杨善让.汽轮机凝汽设备及运行管理[M]北京:中国水利水电出版社,1993.
  • 6孙息生.电站冷凝器冷却管的振动[J]电站辅机,1986(04):20-25.
  • 7孙息生.电站冷凝器的运行与维护[J]电站辅机,1984(05):24-29.
  • 8钱颂文.换热器流体诱导振动基础[M]武汉:华中理工大学出版社,1988.
  • 9Tiejun Wu,Karen Vierow. Local heat transfer measurements of steam/air mixtures in horizontal condenser tubes[J].International Journal of Heat and Mass Transfer,2006,(49):2491-2501.
  • 10Prieto M M,Suarez I M,Montanes E. Analysis of the thermal performance of a church window steam condenser for different operational conditions using three models[J].Applied Thermal Engineering,2003,(23):163-178.

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部