摘要
介绍了在洛阳热电厂改扩建工程中 ,1号俄制发电机定子绕组直流耐压试验时被击穿后的击穿点查找和击穿原因分析 ,以及发电机的修复过程。
During the work of the extension and renovation of Luoyang Thermal Power Plant the stator winding of generator No. 1 was broken down in the DC voltage withstand test. In this paper a method for searching the breakdown position and the analysis on the reason which causes the breakdown is presented. The repair process of the generator is also described.
出处
《电网技术》
EI
CSCD
北大核心
2000年第10期63-65,共3页
Power System Technology
关键词
汽轮发电机
定子绕组
击穿
故障处理
generator
DC voltage withstand test
stator winding of generator
breakdown