期刊文献+

X光大动态条纹变像管优化设计与评价 被引量:1

Optimization Design and Calibration of a High Dynamic Range X-Ray Streak Camera
原文传递
导出
摘要 优化设计了一种大动态范围的X光条纹变像管。该管采用圆筒型电极结构,通过提高加速电压和优化电子光学系统来减小空间电荷效应的影响,并使用调制传递函数模拟了高压电子光学系统的时空特性。采用Au阴极和大动态微通道板(MCP),以进一步扩大条纹变像管动态范围。采用Nd:YLF激光器平台和动态扫描电路对条纹变像管的性能进行了实验评价,激光器输出光脉冲宽度为8ps,动态测试结果显示,该条纹变像管动态范围高于1000,时间分辨率优于14ps,动态空间分辨率优于15lp/mm。实验结果表明,该变像管性能达到设计要求,可基本满足超快诊断的需求,同时表明优化方向和设计方案是正确的。 A kind of cylinder-type electrode and high dynamic range X-ray streak camera has been optimally designed and developed. By improving the accelerating field, optimizing electronic optical system, the spatial and temporal characteristics of the electronic optical system is obtained with the modulation transfer function (MTF). By using the gold cathode (Au) and the large dynamic microchannel plate (MCP), the streak tube's dynamic range is further enlarged. Experimental test is carried out by Nd: YLF laser (8 ps) and dynamic scanning circuit, and the results show that the dynamic range is more than 1000, the time resolution is less than 14 ps, and the dynamic spatial resolution is over the 15 lp/mm. This indicates that the performance of the streak tube receches the design requirements and meet the demand of the ultrafast diagnostics. Meanwhile, the optimization direction and the program design is correct.
出处 《光学学报》 EI CAS CSCD 北大核心 2013年第F06期123-128,共6页 Acta Optica Sinica
基金 国家自然科学基金(60901036)资助课题.
关键词 X射线光学 X光条纹变像管 动态范围 时间分辨率 动态空间分辨率 X-ray optics X-ray streak camera dynamic range time resolution dynamic spatial resolution
  • 相关文献

参考文献13

  • 1彭晓世,王峰,唐道润,刘慎业,蒋小华,刘永刚.聚变反应历程测量系统研制及应用[J].光学学报,2011,31(1):129-134. 被引量:8
  • 2Valerii Losovoi, Il'ya Ushkov, Eduard Prokhorenko et al.. 200 femtosecond streak camera (development and dynamic measurements) [C]. SPIE, 2003, 4948: 297-304.
  • 3孙剑峰, 魏靖松, 王天骄 等. 大视场条纹管激光雷达设计及成像实验研究[J]. 光学学报, 2011, 31(s1): s100413.
  • 4R. T. eagleton, S. F. James. Dynamic range measurements on streak image tubes with internal and external micro-channel plate image amplification [J]. Rev. Sci. Instrum., 2003, 74(3): 2215.
  • 5C. Bonte, M. Harmand, F. Dorchies et al.. High dynamic range streak camera for suboicosecond time-resolved X-ray spectroscopy [J]. Rev. Sci. Instrum., 2007, 78(4): 043503.
  • 6Teruo Takeshita, Kazutaka Suauki, Katsuguki Kinoshita. Development of a high dynamic range streak camera [C]. SPIE, 2001, 4183: 255-260.
  • 7廖华,杨勤劳,张劲松,郭宝平,周军兰,牛丽红.大动态范围长狭缝条纹相机系统[J].强激光与粒子束,2008,20(9):1558-1562. 被引量:10
  • 8潘京生,吕景文,李燕红,周建勋.无膜微通道板第三代像增强器的可行性及技术途径探究[J].光学学报,2012,32(3):273-279. 被引量:5
  • 9V. S. Belolipetski, P. B. Gornostaev, V. I. Lozovoi et al.. 10 ps X-ray streak camera [C]. SPIE, 2009, 7126: 71261C.
  • 10田进寿,白永林,刘百玉,欧阳娴,白晓红,杨文正,王琛.飞秒条纹变相管的设计[J].光子学报,2006,35(12):1832-1836. 被引量:17

二级参考文献73

  • 1曹根瑞,俞信,胡新奇.光子计数成像技术及其应用[J].光学学报,1996,16(2):167-172. 被引量:3
  • 2陈敏,赵宝升,盛立志,田进寿.多狭缝条纹变相管的设计[J].光子学报,2006,35(9):1309-1312. 被引量:16
  • 3金光,张亮,胡福生.大F数高分辨率空间望远镜光学系统[J].光学精密工程,2007,15(2):155-159. 被引量:20
  • 4李思宁,王骐,刘金波,广宇昊,李慧子.条纹管激光成像系统空间分辨力实验研究[J].光学学报,2007,27(6):1023-1026. 被引量:12
  • 5John D. Lindl, Peter Amendt, Richard L. Berger et al.. The physics basis for ignition using indirect-drive targets on the National Ignition Facility[J].Phys. Plasmas, 2004, 11(2): 339-491.
  • 6R. A. Lerche, D. W. Phillion, G. L. Tietbohl. 25 ps neutron detector for measuring ICF-target burn history[J].Rev. Scient. Instrum., 1995, 66(1): 933-935.
  • 7C. Stoeckl, V. Yu. Glebov, S. Roberts et al.. Ten-inch manipulator-based neutron temporal diagnostic for cryogenic experiments on OMEGA[J].Rev. Scient. Instrum., 2003, 74(3): 1713-1716.
  • 8R. A. Lerche , M. D. Cable. Fusion reaction-rate measurement-Nova and NIF[J].UCRL-LR-105821-96-3, 1996.
  • 9M. J. Moran, R. A. Lerche, G. Mant. Optical lightpipe as a high-band width fusion diagnostic[J].Rev. Scient. Instrum., 2006, 77(10): 10E718.
  • 10J. M. Mack, S. E. Caldwell, S. C. Evans et al.. Multiplexed gas Cherenkov detector for reaction-history measurements[J].Rev. Scient. Instrum., 2006, 77(10): 10E728.

共引文献46