期刊文献+

分光光度法测定含银功能纤维中的银含量 被引量:10

Determination of Silver Content in Silver-Contained Functional Fiber by Spectrophotometry
下载PDF
导出
摘要 利用双硫腙一四氯化碳萃取分光光度法对含银功能性纤维中的银元素含量进行分析测定。对3种样品消解方法进行了优化选择,并对检测波长、吸光度稳定性、检出限、方法精确度等进行了考察。实验结果表明,方法的最低低检出量为0.3μg,测定结果的相对标准偏差为2.1%(n=9)。在0.50,1.00,2.00mg/kg3个水平的加标回收率为94.0%~98.5%。该方法可用于含银功能性纤维中的银含量测定。 The silver content in silver-contained functional fiber was determined by dithizone-carbon tetrachloride extraction spectrophotometry. Three sample pre-treatment methods were compared and optimized. The selection of wavelength, stability of absorbance, detection limit, accuracy and precision of the method were discussed. The experiment results showed that the detection limit was 0.3 μ g and the relative standard deviation was 2.1%(n=9). The recovery rate at 0.50,1.00,2.00 mg/kg level was 94.0%-98.5%. The method can be used to determine the silver content in silver-contained functional fiber.
出处 《化学分析计量》 CAS 2013年第4期21-23,共3页 Chemical Analysis And Meterage
基金 江苏出入境检验检疫局科研项目(2009KJ17)
关键词 含银功能性纤维 银含量 双硫腙四氯化碳 分光光度法 silver-contained functional fiber silver content dithizone--carbon tetrachloride spectrophotometry
  • 相关文献

参考文献7

二级参考文献27

共引文献35

同被引文献162

引证文献10

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部