摘要
详述小尿素地下槽V8305液位计LT-80461改造的必要性,详细分析了液位计频繁出现故障的原因,着重介绍了液位计的改造过程,阐明了改造工作的重要性,对于日常使用操作具有指导意义,拓宽了处理问题的思路。
Detailing the necessity of the transformation of Small urea underground tank V8305 level gauge LT-80461, detailed analysis the frequent cause of a failure in level gauge, highlighting the level gauge transformation process, Illustrates the importance of the work of reform, the guiding significance of daily operation use, broadening the idea of dealing with the problem.
关键词
卡套
过滤减压阀
地下槽
节流孔板
膜盒
Card sets Filter regulator Underground tank Restriction orifice Sylphon